Magnetic Micro-Solid-Phase Extraction Using a Novel Carbon-Based Composite Coupled with HPLC-MS/MS for Steroid Multiclass Determination in Human Plasma.
Speltini, Andrea; Merlo, Francesca; Maraschi, Federica; Marrubini, Giorgio; Faravelli, Anna; Profumo, Antonella.
Afiliação
  • Speltini A; Department of Drug Sciences, University of Pavia, 27100 Pavia, Italy.
  • Merlo F; Department of Chemistry, University of Pavia, 27100 Pavia, Italy.
  • Maraschi F; Department of Chemistry, University of Pavia, 27100 Pavia, Italy.
  • Marrubini G; Department of Drug Sciences, University of Pavia, 27100 Pavia, Italy.
  • Faravelli A; Department of Chemistry, University of Pavia, 27100 Pavia, Italy.
  • Profumo A; Department of Chemistry, University of Pavia, 27100 Pavia, Italy.
Molecules ; 26(7)2021 Apr 03.
Article em En | MEDLINE | ID: mdl-33916782
ABSTRACT
A micron-sized sorbent, Magn-Humic, has been prepared by humic acids pyrolysis onto silica-coated magnetite. The material was characterized by scanning electron microscopy (SEM), transmission electron microscopy (TEM), energy dispersive spectroscopy (EDS), thermogravimetric analysis (TGA), and Brunauer, Emmett, and Teller (BET) surface area measurements and applied for simultaneous magnetic solid-phase extraction (MSPE) of glucocorticoids, estrogens, progestogens, and androgens at ng mL-1 levels from human plasma followed by high-performance liquid chromatography coupled with mass spectrometry (HPLC-MS/MS). Due to the low affinity for proteins, steroids extraction was done with no need for proteins precipitation/centrifugation. As highlighted by a design of experiments, MSPE was performed on 250 µL plasma (after 14 dilution) by 50 mg Magn-Humic (reusable for eight extractions) achieving quantitative recovery and satisfying clean-up. This was improved by washing (2 mL 2% v/v formic acid) prior to analytes elution by 0.5 mL 11 v/v methanol-acetonitrile followed by 0.5 mL methanol; eluate reduction to 0.25 mL compensated the initial sample dilution. The accuracy was assessed in certified blank fetal bovine serum and in human plasma, gaining satisfactory recovery in the range 65-122%, detection limits in the range 0.02-0.3 ng mL-1 (0.8 ng mL-1 for 17-ß-estradiol) and suitable inter-day precision (relative standard deviation (RSD) <14%, n = 3). The method was evaluated in terms of selectivity, sensitivity, matrix-effect, instrumental carry-over, and it was applied to human plasma samples.