Your browser doesn't support javascript.
loading
Evaluation of N95 respirator ultraviolet decontamination and clinical reuse with quantitative fit testing.
Wanner, Gregory K; Ader, Douglas; Caplan, Richard; Padaki, Amit S; Ravert, Debra; Drees, Marci.
Afiliação
  • Wanner GK; Department of Emergency Medicine, ChristianaCare, Newark, Delaware.
  • Ader D; Department of Emergency Medicine, ChristianaCare, Newark, Delaware.
  • Caplan R; Value Institute, ChristianaCare, Newark, Delaware.
  • Padaki AS; Department of Emergency Medicine, ChristianaCare, Newark, Delaware.
  • Ravert D; Department of Emergency Medicine, ChristianaCare, Newark, Delaware.
  • Drees M; Departments of Medicine, Quality and Patient Safety, ChristianaCare, Newark, Delaware.
Infect Control Hosp Epidemiol ; 43(9): 1272-1274, 2022 09.
Article em En | MEDLINE | ID: mdl-33934738
ABSTRACT
The supply of N95 respirators has been severely strained by the coronavirus disease 2019 (COVID-19) pandemic. We used quantitative fit-testing to evaluate 16 participants and 45 respirators through up to 4 rounds of ultraviolet decontamination and clinical reuse. The mean fit-test failure rate was 29.7%, and the probability of failure increased through N95 reuse.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Respiradores N95 / COVID-19 Limite: Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Respiradores N95 / COVID-19 Limite: Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article