Your browser doesn't support javascript.
loading
Comparison of new approach of GC-HRMS (Q-Orbitrap) to GC-MS/MS (triple-quadrupole) in analyzing the pesticide residues and contaminants in complex food matrices.
Belarbi, Saida; Vivier, Martin; Zaghouani, Wafa; Sloovere, Aude De; Agasse-Peulon, Valérie; Cardinael, Pascal.
Afiliação
  • Belarbi S; Normandie Univ, Laboratoire SMS-EA3233, UNIROUEN, FR3038, Place Emile Blondel, F-76821, Mont-Saint-Aignan Cedex, France; SGS France laboratoire de Rouen, Technopôle du Madrillet, 65 Avenue Ettore Bugatti, Saint Etienne du Rouvray F-76801 Cedex, France.
  • Vivier M; SGS France laboratoire de Rouen, Technopôle du Madrillet, 65 Avenue Ettore Bugatti, Saint Etienne du Rouvray F-76801 Cedex, France.
  • Zaghouani W; SGS France laboratoire de Rouen, Technopôle du Madrillet, 65 Avenue Ettore Bugatti, Saint Etienne du Rouvray F-76801 Cedex, France.
  • Sloovere A; SGS France laboratoire de Rouen, Technopôle du Madrillet, 65 Avenue Ettore Bugatti, Saint Etienne du Rouvray F-76801 Cedex, France.
  • Agasse-Peulon V; Normandie Univ, Laboratoire SMS-EA3233, UNIROUEN, FR3038, Place Emile Blondel, F-76821, Mont-Saint-Aignan Cedex, France.
  • Cardinael P; Normandie Univ, Laboratoire SMS-EA3233, UNIROUEN, FR3038, Place Emile Blondel, F-76821, Mont-Saint-Aignan Cedex, France. Electronic address: pascal.cardinael@univ-rouen.fr.
Food Chem ; 359: 129932, 2021 Oct 15.
Article em En | MEDLINE | ID: mdl-33945988
ABSTRACT
Performances of multiresidue analysis of one hundred of pesticides and contaminants, using GC-Q-Orbitrap method in full scan mode were compared to those obtained with GC-triple-quadrupole method in multiple reaction monitoring mode. In terms of sensitivity, 86% of molecules exhibited lower limit of detection values using GC-Q-Orbitrap than using GC-triple-quadrupole. For the GC-Q-Orbitrap method, more than 85% of the pesticides and contaminants showed good recovery [70-120%] in wheat samples, with relative standard deviation values < 20%. GC-Q-Orbitrap method appeared the most sensitive for most pesticides studied in wheat with limit of quantification values ranged between 0.1 µg/kg and 4 µg/kg. Moreover, the matrix effect was acceptable in wheat extracts for 84 molecules but strong suppression of the chromatographic signal was observed for 16 molecules for the GC-Q-Orbitrap method. The injection of unpurified wheat extracts spiked at 10 µg/kg proved the potential of the GC-Q-Orbitrap method for use in performing high-throughput pesticide screening.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Resíduos de Praguicidas / Contaminação de Alimentos / Espectrometria de Massas em Tandem / Cromatografia Gasosa-Espectrometria de Massas Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Resíduos de Praguicidas / Contaminação de Alimentos / Espectrometria de Massas em Tandem / Cromatografia Gasosa-Espectrometria de Massas Idioma: En Ano de publicação: 2021 Tipo de documento: Article