Your browser doesn't support javascript.
loading
The significance of synovial biopsy in the diagnostic workup of the low-grade periprosthetic joint infection of shoulder arthroplasty.
Mederake, Moritz; Hofmann, Ulf Krister; Fink, Bernd.
Afiliação
  • Mederake M; Department of Orthopaedic Surgery, University Hospital Tübingen, Hoppe Seyler-Str. 3, 72076, Tübingen, Germany. moritz.mederake@med.uni-tuebingen.de.
  • Hofmann UK; Department of Orthopaedic Surgery, University Hospital Tübingen, Hoppe Seyler-Str. 3, 72076, Tübingen, Germany.
  • Fink B; Department of Joint Replacement, Orthopaedic Clinic Markgröningen, Kurt-Lindemann-Weg 10, 71706, Markgröningen, Germany.
Arch Orthop Trauma Surg ; 142(11): 3157-3164, 2022 Nov.
Article em En | MEDLINE | ID: mdl-33991235
ABSTRACT

INTRODUCTION:

A common reason for painful shoulder arthroplasties and revision surgery is a low-grade periprosthetic joint infection (PJI). Diagnosing a low-grade infection is, however, a major diagnostic challenge. This applies even more to the shoulder, which differs from other large joints in terms of clinical features and microbiological spectrum. Aim of this study was to evaluate the diagnostic value of the synovial biopsy in the diagnostic workup of low-grade PJI of the shoulder. MATERIALS AND

METHODS:

A retrospective evaluation was conducted on 56 patients receiving revision surgery on their shoulder arthroplasty. A standardized preoperative workup was performed comprising CRP value, leukocyte blood count, synovial fluid microbiological analyses and leukocyte count from joint aspiration, and five synovial biopsy samples for bacteriologic and histologic analysis obtained through an arthroscopic approach. During revision surgery, five samples of periprosthetic tissue were harvested for bacteriologic and histologic analyses. The MSIS-Criteria 2014 were used to evaluate the diagnostic results.

RESULTS:

In total, 15 of 56 revised prostheses turned out as PJI (27%). When applying our diagnostic workup, we obtained a sensitivity of 67% with a specificity of 95%. When performing a subgroup analysis on those patients that had received diagnostic biopsy, a sensitivity of 100% and a specificity of 83% could be achieved. With a sensitivity and specificity of 90% and 83%, respectively, the biopsy is the single method with the highest diagnostic value.

CONCLUSIONS:

The sensitivity of only 67% of our standard workup emphasizes the difficulty to adequately diagnose low-grade infections after shoulder arthroplasty. The excellent specificity of 95% ensures, however, that non-infected prostheses are not incorrectly explanted. This study highlights that synovial biopsy has a high diagnostic value and should be done prior to complex revision surgeries to raise sensitivity in diagnosing a PJI.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Artrite Infecciosa / Infecções Relacionadas à Prótese / Artroplastia de Quadril / Artroplastia do Ombro Tipo de estudo: Diagnostic_studies / Observational_studies Limite: Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Artrite Infecciosa / Infecções Relacionadas à Prótese / Artroplastia de Quadril / Artroplastia do Ombro Tipo de estudo: Diagnostic_studies / Observational_studies Limite: Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article