Your browser doesn't support javascript.
loading
Gold-silver nanoparticles modified electrochemical sensor array for simultaneous determination of chromium(III) and chromium(VI) in wastewater samples.
Zhao, Ke; Ge, Liya; Wong, Ten It; Zhou, Xiaodong; Lisak, Grzegorz.
Afiliação
  • Zhao K; Residues and Resource Reclamation Centre (R3C), Nanyang Environment and Water Research Institute, Nanyang Technological University, 1 Cleantech Loop, Clean Tech One, 637141, Singapore.
  • Ge L; Residues and Resource Reclamation Centre (R3C), Nanyang Environment and Water Research Institute, Nanyang Technological University, 1 Cleantech Loop, Clean Tech One, 637141, Singapore. Electronic address: LYGe@ntu.edu.sg.
  • Wong TI; Institute of Materials Research and Engineering, A*STAR (Agency for Science, Technology and Research), 2 Fusionopolis Way, #08-03, Innovis, 138634, Singapore.
  • Zhou X; Institute of Materials Research and Engineering, A*STAR (Agency for Science, Technology and Research), 2 Fusionopolis Way, #08-03, Innovis, 138634, Singapore.
  • Lisak G; Residues and Resource Reclamation Centre (R3C), Nanyang Environment and Water Research Institute, Nanyang Technological University, 1 Cleantech Loop, Clean Tech One, 637141, Singapore; School of Civil and Environmental Engineering, Nanyang Technological University, 50 Nanyang Avenue, 639798, Singapo
Chemosphere ; 281: 130880, 2021 Oct.
Article em En | MEDLINE | ID: mdl-34029966
ABSTRACT
The oxidation state of ions is a crucial aspect that often has been overlooked when determining the toxicity of chromium (Cr) species in environmental samples. In this study, a novel electrochemical sensor array based on gold-silver nanoparticles modified electrodes was developed for simultaneous determination of the two main chromium species (Cr(III) and (VI)). Specifically, the working electrodes of screen-printed carbon electrodes (SPCEs) were modified with silver-gold bimetallic nanoparticles through electrochemical deposition for detection of Cr(VI). The silver-gold bimetallic nanoparticles were further oxidized to form stable silver-gold bimetallic oxide nanoparticles for the detection of Cr(III). The results showed that the addition of silver with a theoretical value of 1% of gold could contribute to the formation and stabilization of oxides on the surface of gold nanoparticles. After characterization, the two kinds of electrodes were integrated as an electrochemical sensor array for selective and sensitive detection of Cr(VI) and Cr(III). The linear range and limit of detection (LOD, identified by three times of signal-to-noise ratio) were found to be 0.05-5 ppm and 0.1 ppb for Cr(VI), and 0.05-1 ppm and 0.1 ppb for Cr(III), respectively. Finally, the electrochemical sensor array was proven for successful detection of Cr(VI) and Cr(III) in tap water, artificial saliva and artificial sweat samples, and monitoring of Cr(VI) and Cr(III) in chromium-containing wastewater treatment process. Combined with a handheld dual-channel electrochemical device, the simultaneous determination of Cr(VI), Cr(III) and total chromium contents can be easily achieved for various samples.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Nanopartículas Metálicas / Ouro Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Nanopartículas Metálicas / Ouro Idioma: En Ano de publicação: 2021 Tipo de documento: Article