Your browser doesn't support javascript.
loading
Serial evaluation of vascular responses after implantation of everolimus-eluting coronary stent by optical coherence tomography.
Kaul, Upendra; Abhyankar, Atul; K Abhaichand, Rajpal; Bhagwat, Ajit; Sengottuvelu, Gunasekaran; Gopalan Bahuleyan, Charantharayil; Arambam, Priyadarshini; Yumnam, Diana.
Afiliação
  • Kaul U; Batra Heart Centre, Batra Hospital and Medical Research Centre, New Delhi, India.
  • Abhyankar A; Department of Cardiology, Shri B. D. Mehta Mahavir Heart Institute, Surat, India.
  • K Abhaichand R; Department of Cardiology, G Kuppuswamy Naidu Memorial Hospital, Coimbatore, India.
  • Bhagwat A; Department of Cardiology, Kamalnayan Bajaj Hospital, Aurangabad, India.
  • Sengottuvelu G; Department of Cardiology, Apollo Hospitals, Chennai, India.
  • Gopalan Bahuleyan C; Cardiovascular Centre, Ananthapuri Hospitals and Research Institute, Kerala, India.
  • Arambam P; Batra Heart Centre, Batra Hospital and Medical Research Centre, New Delhi, India.
  • Yumnam D; Batra Heart Centre, Batra Hospital and Medical Research Centre, New Delhi, India.
Catheter Cardiovasc Interv ; 99(2): 381-390, 2022 02.
Article em En | MEDLINE | ID: mdl-34061443
AIM: To evaluate healing response at strut-level and cross-section level after implanting an ultra-thin strut, everolimus-eluting stent with biodegradable polymer (Tetrilimus) using optical coherence tomography (OCT) at 3 and 6 months. METHODS: This was prospective, multi-centre, single-arm, and investigator-initiated study performed at seven Indian sites between January, 2017 and September, 2018. OCT evaluations were performed in 57 patients who underwent Tetrilimus stent implantation. Follow-up OCT was scheduled at 3 months for first 16 patients and at 6 months for 41 patients. Primary outcomes included degree of strut coverage, malapposition and thickness of neointimal hyperplasia (NIH) over covered struts. RESULTS: Sixty one Tetrilimus stents were implanted to treat 59 lesions in 57 patients. Paired (baseline and follow-up) OCT data was available for 12 patients and 30 patients at 3 and 6 months, respectively. At 3 months, rapid early healing was indicated by 95.48% covered struts per lesion with very low (0.11 ± 0.06 mm) NIH. At 6 months, NIH accumulation was greater (0.21 ± 0.07 mm) as compared to 3 months. 99.77% of struts per lesion were covered at 6 months. There was a very symmetrical healing as shown by very low eccentricity index. There was no difference in vascular healing between stents with small to moderate size vessels (≤3.00 mm) and large size vessels (>3.00 mm). CONCLUSION: Present study demonstrated nearly complete endothelization and low NIH accumulation at 3 and 6 months following implantation of ultra-thin strut everolimus-eluting biodegradable polymer-coated Tetrilimus stent. Moreover, though being an ultra-thin strut stent, there was no difference in vascular healing and eccentricity after implantation of the Tetrilimus stents with smaller and larger diameters.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Doença da Artéria Coronariana / Stents Farmacológicos / Intervenção Coronária Percutânea Tipo de estudo: Etiology_studies / Observational_studies Limite: Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Doença da Artéria Coronariana / Stents Farmacológicos / Intervenção Coronária Percutânea Tipo de estudo: Etiology_studies / Observational_studies Limite: Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article