Achieving Precise Spectral Analysis and Imaging Simultaneously with a Mode-Resolved Dual-Comb Interferometer.
Deng, Zejiang; Liu, Yang; Zhu, Zhiwei; Luo, Daping; Gu, Chenglin; Zuo, Zhong; Xie, Gehui; Li, Wenxue.
Afiliação
  • Deng Z; State Key Laboratory of Precision Spectroscopy, East China Normal University, Shanghai 200062, China.
  • Liu Y; State Key Laboratory of Precision Spectroscopy, East China Normal University, Shanghai 200062, China.
  • Zhu Z; State Key Laboratory of Precision Spectroscopy, East China Normal University, Shanghai 200062, China.
  • Luo D; State Key Laboratory of Precision Spectroscopy, East China Normal University, Shanghai 200062, China.
  • Gu C; State Key Laboratory of Precision Spectroscopy, East China Normal University, Shanghai 200062, China.
  • Zuo Z; State Key Laboratory of Precision Spectroscopy, East China Normal University, Shanghai 200062, China.
  • Xie G; State Key Laboratory of Precision Spectroscopy, East China Normal University, Shanghai 200062, China.
  • Li W; State Key Laboratory of Precision Spectroscopy, East China Normal University, Shanghai 200062, China.
Sensors (Basel) ; 21(9)2021 May 03.
Article em En | MEDLINE | ID: mdl-34063563
ABSTRACT
In this paper, we report a scheme providing precise spectral analysis and surface imaging, simultaneously, based on a high-coherence dual-comb interferometer. With two tightly phase-locking frequency combs, we demonstrate a high-coherence dual-comb interferometer (DCI) covering 188 to 195 THz (1538.5 to 1595.7 nm) with comb-tooth resolution and a max spectral signal-to-noise ratio (SNR) of 159.7. The combination of the high-coherence dual-comb spectrometer and a reference arm simultaneously enables gas absorption spectroscopy and for the absolute distance information to be obtained in one measurement. As a demonstration, we measure the spectrum of CO2 and CO. From the same interferograms, we demonstrate that distance measurement, by time-of-flight (TOF), can be resolved with an rms precision of 0.53 µm after averaging 140 images and a measurement time of 1 s. Finally, we demonstrate that non-contact surface imaging, using 2D mechanical scanning, reaches lateral resolution of 40 µm. The longitudinal precision is 0.68 µm with a measurement time of 0.5 s. It verifies that DCS has the potential to be applied in standoff detection, environmental pollution monitors, and remote sensing.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2021 Tipo de documento: Article