Your browser doesn't support javascript.
loading
Evaluation of acrylamide-based molecularly imprinted polymer thin-sheets for specific protein capture-a myoglobin model.
Sullivan, Mark V; Dennison, Sarah R; Hayes, Joseph M; Reddy, Subrayal M.
Afiliação
  • Sullivan MV; Dr. M. V. Sullivan and Prof. S. M. Reddy, Department of Chemistry, School of Natural Sciences, University of Central Lancashire, Preston, PR1 2HE, United Kingdom.
  • Dennison SR; Dr. S. R. Dennison and Dr. J. M. Hayes, School of Pharmacy and Biomedical Sciences, University of Central Lancashire, Preston, PR1 2HE, United Kingdom.
  • Hayes JM; Dr. S. R. Dennison and Dr. J. M. Hayes, School of Pharmacy and Biomedical Sciences, University of Central Lancashire, Preston, PR1 2HE, United Kingdom.
  • Reddy SM; Dr. M. V. Sullivan and Prof. S. M. Reddy, Department of Chemistry, School of Natural Sciences, University of Central Lancashire, Preston, PR1 2HE, United Kingdom.
Biomed Phys Eng Express ; 7(4)2021 06 18.
Article em En | MEDLINE | ID: mdl-34107465
ABSTRACT
We evaluate a series of thin-sheet hydrogel molecularly imprinted polymers (MIPs), using a family of acrylamide-based monomers, selective for the target protein myoglobin (Mb). The simple production of the thin-sheet MIP offers an alternative biorecognition surface that is robust, stable and uniform, and has the potential to be adapted for biosensor applications. The MIP containing the functional monomerN-hydroxymethylacrylamide (NHMAm), produced optimal specific rebinding of the target protein (Mb) with 84.9% (± 0.7) rebinding and imprinting and selectivity factors of 1.41 and 1.55, respectively. The least optimal performing MIP contained the functional monomerN,N-dimethylacrylamide (DMAm) with 67.5% (± 0.7) rebinding and imprinting and selectivity factors of 1.11 and 1.32, respectively. Hydrogen bonding effects, within a protein-MIP complex, were investigated using computational methods and Fourier transform infrared (FTIR) spectroscopy. The quantum mechanical calculations predictions of a red shift of the monomer carbonyl peak is borne-out within FTIR spectra, with three of the MIPs, acrylamide, N-(hydroxymethyl) acrylamide, andN-(hydroxyethyl) acrylamide, showing peak downshifts of 4, 11, and 8 cm-1, respectively.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Impressão Molecular Tipo de estudo: Prognostic_studies Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Impressão Molecular Tipo de estudo: Prognostic_studies Idioma: En Ano de publicação: 2021 Tipo de documento: Article