Your browser doesn't support javascript.
loading
AnaLysIs of Both sex and device specific factoRs on outcomes in pAtients with non-ischemic cardiomyopathy (BIO-LIBRA): Design and clinical protocol.
Kutyifa, Valentina; Brown, Mary W; Beck, Christopher A; McNitt, Scott; Miller, Crystal; Cox, Karlene; Zareba, Wojciech; Rosero, Spencer Z; Gleva, Marye J; Poole, Jeanne E.
Afiliação
  • Kutyifa V; Clinical Cardiovascular Research Center, Cardiology Division, Department of Medicine, University of Rochester Medical Center, Rochester, New York.
  • Brown MW; Clinical Cardiovascular Research Center, Cardiology Division, Department of Medicine, University of Rochester Medical Center, Rochester, New York.
  • Beck CA; Department of Biostatistics and Computational Biology, University of Rochester Medical Center, Rochester, New York.
  • McNitt S; Clinical Cardiovascular Research Center, Cardiology Division, Department of Medicine, University of Rochester Medical Center, Rochester, New York.
  • Miller C; BIOTRONIK Inc, Lake Oswego, Oregon.
  • Cox K; BIOTRONIK Inc, Lake Oswego, Oregon.
  • Zareba W; Clinical Cardiovascular Research Center, Cardiology Division, Department of Medicine, University of Rochester Medical Center, Rochester, New York.
  • Rosero SZ; Clinical Cardiovascular Research Center, Cardiology Division, Department of Medicine, University of Rochester Medical Center, Rochester, New York.
  • Gleva MJ; Washington University in St Louis School of Medicine, St. Louis, Missouri.
  • Poole JE; Department of Cardiology, University of Washington, Seattle, Washington.
Heart Rhythm O2 ; 1(5): 376-384, 2020 Dec.
Article em En | MEDLINE | ID: mdl-34113895
ABSTRACT

BACKGROUND:

Outcomes of patients with nonischemic cardiomyopathy and low ejection fraction implanted with an implantable cardioverter-defibrillator (ICD) or cardiac resynchronization therapy with a defibrillator (CRT-D), especially in contemporary, real-life cohorts, are not fully understood.

OBJECTIVE:

We aimed to better characterize outcomes of death and ventricular tachyarrhythmias in patients with nonischemic cardiomyopathy, implanted with an ICD or CRT-D, and specifically assess differences by sex.

METHODS:

The AnaLysIs of Both Sex and Device Specific FactoRs on Outcomes in PAtients with Non-Ischemic Cardiomyopathy (BIO-LIBRA) study was designed to prospectively assess outcomes of device-treated ventricular tachyarrhythmias and all-cause mortality events in nonischemic cardiomyopathy patients, indicated for an ICD or CRT-D implantation for the primary prevention of sudden cardiac death (SCD), with a specific focus on sex differences. We will enroll a total of 1000 subjects across 50 U.S. sites and follow patients for up to 3 years.

RESULTS:

The primary objective of BIO-LIBRA is to evaluate the combined risk of all-cause mortality and treated ventricular tachycardia (VT) or ventricular fibrillation (VF) events by subject sex and by implanted device type. We will also assess all-cause mortality, VT or VF alone, cardiac death, and SCD in the total cohort, as well as by subject sex and by the implanted device type. In addition, the previously validated Seattle Proportional Risk Model (SPRM) will be used to compare the SPRM predicted incidence of SCD to the observed incidence.

CONCLUSIONS:

The BIO-LIBRA study will provide novel and contemporary information regarding outcomes in patients with a NICM who receive a defibrillator.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Tipo de estudo: Guideline / Prognostic_studies Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Tipo de estudo: Guideline / Prognostic_studies Idioma: En Ano de publicação: 2020 Tipo de documento: Article