Your browser doesn't support javascript.
loading
Sensitive Quantification of Nicotine in Bronchoalveolar Lavage Fluid by Acetone Precipitation Combined With Isotope-Dilution Liquid Chromatography-Tandem Mass Spectrometry.
Xia, Baoyun; Blount, Benjamin C; Wang, Lanqing.
Afiliação
  • Xia B; Tobacco and Volatiles Branch, Division of Laboratory Sciences, National Center for Environmental Health, U.S. Centers for Disease Control and Prevention (CDC), 4770 Buford Highway, Mail Stop S103-3, Atlanta, Georgia 30341, United States.
  • Blount BC; Tobacco and Volatiles Branch, Division of Laboratory Sciences, National Center for Environmental Health, U.S. Centers for Disease Control and Prevention (CDC), 4770 Buford Highway, Mail Stop S103-3, Atlanta, Georgia 30341, United States.
  • Wang L; Tobacco and Volatiles Branch, Division of Laboratory Sciences, National Center for Environmental Health, U.S. Centers for Disease Control and Prevention (CDC), 4770 Buford Highway, Mail Stop S103-3, Atlanta, Georgia 30341, United States.
ACS Omega ; 6(22): 13962-13969, 2021 Jun 08.
Article em En | MEDLINE | ID: mdl-34124421
The United States experienced an outbreak of e-cigarette, or vaping, product use-associated lung injury (EVALI) that began in August 2019. Patient diagnosis and treatment sometimes involved bronchoscopy and collection of the bronchoalveolar lavage (BAL) fluid. Although this matrix has been useful for understanding some chemical exposures in the lungs, no methods existed for measuring the nicotine content. Therefore, we developed a simple and sensitive method for measuring nicotine in the BAL fluid. Nicotine was extracted from the BAL fluid using acetone precipitation in a 96-well plate format to increase the sample throughput (200 samples/day). We optimized liquid chromatography column conditions (e.g., mobile phase, column temperature) and mass spectrometry parameters to improve the signal-to-noise ratio and lower limits of detection (LOD) for measuring nicotine in the BAL fluid. The LOD for nicotine in the BAL fluid was 0.050 ng/mL at a sample volume of 40 µL of the BAL fluid. The within-day and between-day imprecision and bias were less than 10%. This method detected nicotine in 15 of 43 BAL fluids from EVALI case patients. This method is useful for understanding recent inhalational exposure to nicotine as part of characterizing EVALI or similar illnesses.

Texto completo: 1 Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Ano de publicação: 2021 Tipo de documento: Article