Your browser doesn't support javascript.
loading
Determination of protein concentration in downstream biomanufacturing processes by in-line index of refraction.
Harris, Steven A; Patel, Bhumit A; Gospodarek, Adrian; Desai, Jayesh; de Janon Gutiérrez, Alejandro; Botonjic-Sehic, Edita; Brower, Mark; Pinto, Nuno D S.
Afiliação
  • Harris SA; Analytics Group, Digital Innovation Program, Central Technology Organization, Pall Corporation, Westborough, Massachusetts, USA.
  • Patel BA; Analytical Research and Development, Merck & Co., Inc., Kenilworth, New Jersey, USA.
  • Gospodarek A; Biologics Process Research and Development, Merck & Co., Inc., Kenilworth, New Jersey, USA.
  • Desai J; Analytical Research and Development, Merck & Co., Inc., Kenilworth, New Jersey, USA.
  • de Janon Gutiérrez A; School of Chemical and Biomolecular Engineering, Georgia Institute of Technology, Atlanta, Georgia, USA.
  • Botonjic-Sehic E; Analytics Group, Digital Innovation Program, Central Technology Organization, Pall Corporation, Westborough, Massachusetts, USA.
  • Brower M; Biologics Process Research and Development, Merck & Co., Inc., Kenilworth, New Jersey, USA.
  • Pinto NDS; Biologics Process Research and Development, Merck & Co., Inc., Kenilworth, New Jersey, USA.
Biotechnol Prog ; 37(5): e3187, 2021 09.
Article em En | MEDLINE | ID: mdl-34164947
ABSTRACT
Protein concentration determination is a necessary in-process control for the downstream operations within biomanufacturing. As production transitions from batch mode to an integrated continuous bioprocess paradigm, there is a growing need to move protein concentration quantitation from off-line to in-line analysis. One solution to fulfill this process analytical technology need is an in-line index of refraction (IoR) sensor to measure protein concentration in real time. Here the performance of an IoR sensor is evaluated through a series of experiments to assess linear response, buffer matrix effects, dynamic range, sensor-to-sensor variability, and the limits of detection and quantitation. The performance of the sensor was also tested in two bioprocessing scenarios, ultrafiltration and capture chromatography. The implementation of this in-line IoR sensor for real-time protein concentration analysis and monitoring has the potential to improve continuous bioprocess manufacturing.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Refratometria / Proteínas Recombinantes / Reatores Biológicos / Anticorpos Monoclonais Limite: Animals / Humans Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Refratometria / Proteínas Recombinantes / Reatores Biológicos / Anticorpos Monoclonais Limite: Animals / Humans Idioma: En Ano de publicação: 2021 Tipo de documento: Article