Your browser doesn't support javascript.
loading
Radiologists and Clinical Trials: Part 2: Practical Statistical Methods for Understanding and Monitoring Independent Reader Performance.
Raunig, David L; Schmid, Annette M; Miller, Colin G; Walovitch, Richard C; O'Connor, Michael; Noever, Klaus; Hristova, Ivalina; O'Neal, Michael; Brueggenwerth, Guenther; Ford, Robert R.
Afiliação
  • Raunig DL; Takeda, 300 Massachusetts Ave, Cambridge, MA, 02139, USA. draunig@snet.net.
  • Schmid AM; Takeda, 300 Massachusetts Ave, Cambridge, MA, 02139, USA.
  • Miller CG; The Bracken Group, Newtown, PA, USA.
  • Walovitch RC; WorldCare Clinical, Boston, MA, USA.
  • O'Connor M; Parexel, Billerica, MA, USA.
  • Noever K; Bioclinica, Basel, Switzerland.
  • Hristova I; Independent Consultant, Vienna, Austria.
  • O'Neal M; Bioclinica, Princeton, NJ, USA.
  • Brueggenwerth G; Bayer Schering Plough AG, Berlin, Germany.
  • Ford RR; Bioclinica, Belle Mead, NJ, USA.
Ther Innov Regul Sci ; 55(6): 1122-1138, 2021 11.
Article em En | MEDLINE | ID: mdl-34244987
Though many clinical trials rely on medical image evaluations for primary or key secondary endpoints, the methods to monitor reader performance are all too often mired in the legacy use of adjudication rates. If misused, this simple metric can be misleading and sometimes entirely contradictory. Furthermore, attempts to overcome the limitations of adjudication rates using de novo or ad hoc methods often ignore well-established research conducted over the last half-century and can lead to inaccurate conclusions or variable interpretations. Underperforming readers can be missed, expert readers retrained, or worse, replaced. This paper aims to standardize reader performance evaluations using proven statistical methods. Additionally, these methods will describe how to discriminate between scenarios of concern and normal medical interpretation variability. Statistical methods are provided for inter-reader and intra-reader variability and bias, including the adjudicator's bias. Finally, we have compiled guidelines for calculating correct sample sizes, considerations for intra-reader memory recall, and applying alternative designs for independent readers.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Radiologistas Tipo de estudo: Guideline Limite: Humans Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Radiologistas Tipo de estudo: Guideline Limite: Humans Idioma: En Ano de publicação: 2021 Tipo de documento: Article