Signal Extraction, Transformation, and Magnification for Ultrasensitive and Specific Detection of Nucleic Acids.
He, Hongfei; Luo, Guangcheng; Zhang, Jun; Tang, Ling; Zhou, Yan; Hu, Bei; Dai, Jianyuan; Huang, Zhen.
Afiliação
  • He H; Key Laboratory of Bio-Resource and Eco-Environment of Ministry of Education, College of Life Sciences, Sichuan University, Chengdu 610065, Sichuan, China.
  • Luo G; Department of Clinical Laboratory, Affiliated Hospital of North Sichuan Medical College, Nanchong 637000, Sichuan, P. R. China.
  • Zhang J; Key Laboratory of Bio-Resource and Eco-Environment of Ministry of Education, College of Life Sciences, Sichuan University, Chengdu 610065, Sichuan, China.
  • Tang L; Key Laboratory of Bio-Resource and Eco-Environment of Ministry of Education, College of Life Sciences, Sichuan University, Chengdu 610065, Sichuan, China.
  • Zhou Y; Key Laboratory of Bio-Resource and Eco-Environment of Ministry of Education, College of Life Sciences, Sichuan University, Chengdu 610065, Sichuan, China.
  • Hu B; Key Laboratory of Bio-Resource and Eco-Environment of Ministry of Education, College of Life Sciences, Sichuan University, Chengdu 610065, Sichuan, China.
  • Dai J; College of Chemistry, Sichuan University, Chengdu 610064, P. R. China.
  • Huang Z; Key Laboratory of Bio-Resource and Eco-Environment of Ministry of Education, College of Life Sciences, Sichuan University, Chengdu 610065, Sichuan, China.
Anal Chem ; 93(30): 10611-10618, 2021 08 03.
Article em En | MEDLINE | ID: mdl-34297543
ABSTRACT
Nucleic acid noises caused by the background and nonspecificity amplifications can jeopardize accurate polymerization and detection of nucleic acids, especially when they are analyzed in low copies. We hypothesize to reduce the noises by designing a system for specific signal extraction, transformation, and magnification to improve the specificity and sensitivity. Herein, by developing an extractor-trigger complex (ET-Combo) for the system, we have established isothermal and hybridizing combined amplifications a one-pot detection system with two-step amplification coupled by ET-Combo. To our surprise, the signal extraction is only successful when ET-Combo is included in the first amplification. Our signal extracting, filtering, and relaying system with ET-Combo is rapid and specific, removing the noises generated during the isothermal amplification under elevated temperatures. To match the first amplification, we have designed and established a hybridizing chain reaction at high temperature. This one-pot system can resist disruption of background noises and allow detection of DNA up to five copies (single digit). With the high sensitivity, specificity, and noise resistance, our system has been successfully used to diagnose clinical samples of human papillomavirus (HPV) with the genotyping specificity.