Your browser doesn't support javascript.
loading
Comparison of the novel VieScope with conventional and video laryngoscope in a difficult airway scenario - a randomized, controlled simulation trial.
Ecker, Hannes; Kolvenbach, Simone; Stranz, Sebastian; Herff, Holger; Wetsch, Wolfgang A.
Afiliação
  • Ecker H; University of Cologne, Medical Faculty, and University Hospital Cologne, Department of Anaesthesiology and Intensive Care Medicine, Kerpener Str. 62, 50937, Cologne, Germany.
  • Kolvenbach S; University of Cologne, Medical Faculty, and University Hospital Cologne, Department of Anaesthesiology and Intensive Care Medicine, Kerpener Str. 62, 50937, Cologne, Germany.
  • Stranz S; University of Cologne, Medical Faculty, and University Hospital Cologne, Department of Anaesthesiology and Intensive Care Medicine, Kerpener Str. 62, 50937, Cologne, Germany.
  • Herff H; University of Cologne, Medical Faculty, and University Hospital Cologne, Department of Anaesthesiology and Intensive Care Medicine, Kerpener Str. 62, 50937, Cologne, Germany.
  • Wetsch WA; University of Cologne, Medical Faculty, and University Hospital Cologne, Department of Anaesthesiology and Intensive Care Medicine, Kerpener Str. 62, 50937, Cologne, Germany. wolfgang.wetsch@uk-koeln.de.
BMC Emerg Med ; 21(1): 90, 2021 07 30.
Article em En | MEDLINE | ID: mdl-34330219
BACKGROUND: Endotracheal intubation continues to be the gold standard for securing the airway in emergency situations. Difficult intubation is still a dreadful situation when securing the airway. OBJECTIVE: To compare VieScope with Glidescope and conventional Macintosh laryngoscopy (MAC) in a simulated difficult airway situation. METHODS: In this randomized controlled simulation trial, 35 anesthesiologists performed endotracheal intubation using VieScope, GlideScope and MAC in a randomized order on a certified airway manikin with difficult airway. RESULTS: For the primary endpoint of correct tube position, no statistical difference was found (p = 0.137). Time until intubation for GlideScope (27.5 ± 20.3 s) and MAC (20.8 ± 8.1 s) were shorter compared to the VieScope (36.3 ± 10.1 s). Time to first ventilation, GlideScope (39.3 ± 21.6 s) and MAC (31.9 ± 9.5 s) were also shorter compared to the VieScope (46.5 ± 12.4 s). There was no difference shown between handling time for VieScope (20.7 ± 7.0 s) and time until intubation with GlideScope or MAC. Participants stated a better Cormack & Lehane Score with VieScope, compared to direct laryngoscopy. CONCLUSION: Rate of correct tracheal tube position was comparable between the three devices. Time to intubation and ventilation were shorter with MAC and Glidescope compared to VieScope. It did however show a comparable handling time to video laryngoscopy and MAC. It also did show a better visualization of the airway in the Cormack & Lehane Score compared to MAC. TRIAL REGISTRATION: The study was registered at the German Clinical Trials Register www.drks.de (Identifier: DRKS00024968 ) on March 31st 2021.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Laringoscópios / Intubação Intratraqueal Tipo de estudo: Clinical_trials / Prognostic_studies Limite: Adolescent / Adult / Aged / Humans / Middle aged Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Laringoscópios / Intubação Intratraqueal Tipo de estudo: Clinical_trials / Prognostic_studies Limite: Adolescent / Adult / Aged / Humans / Middle aged Idioma: En Ano de publicação: 2021 Tipo de documento: Article