Your browser doesn't support javascript.
loading
MRI software for diffusion-perfusion mismatch analysis may impact on patients' selection and clinical outcome.
Pistocchi, Silvia; Strambo, Davide; Bartolini, Bruno; Maeder, Philippe; Meuli, Reto; Michel, Patrik; Dunet, Vincent.
Afiliação
  • Pistocchi S; Diagnostic Neuroradiological Unit, Service of Diagnostic and Interventional Radiology, Department of Medical Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland.
  • Strambo D; Stroke Center, Service of Neurology, Department of Clinical Neurosciences, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland.
  • Bartolini B; Diagnostic Neuroradiological Unit, Service of Diagnostic and Interventional Radiology, Department of Medical Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland.
  • Maeder P; Diagnostic Neuroradiological Unit, Service of Diagnostic and Interventional Radiology, Department of Medical Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland.
  • Meuli R; Diagnostic Neuroradiological Unit, Service of Diagnostic and Interventional Radiology, Department of Medical Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland.
  • Michel P; Stroke Center, Service of Neurology, Department of Clinical Neurosciences, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland.
  • Dunet V; Diagnostic Neuroradiological Unit, Service of Diagnostic and Interventional Radiology, Department of Medical Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland. Vincent.Dunet@chuv.ch.
Eur Radiol ; 32(2): 1144-1153, 2022 Feb.
Article em En | MEDLINE | ID: mdl-34350507
ABSTRACT

OBJECTIVE:

Impact of different MR perfusion software on selection and outcome of patients with acute ischemic stroke (AIS) and large vessel occlusion (LVO) treated by endovascular thrombectomy (EVT) is unclear. We aimed at comparing two commercial MRI software, semi-automated with unadjusted (method A) and adjusted mask (method B), and fully automated (method C) in this setting.

METHODS:

MRI from 144 consecutive AIS patients with anterior circulation LVO was retrospectively analysed. All diffusion- and perfusion-weighted images (DWI-PWI) were post-processed with the three methods using standard thresholds. Concordance for core and hypoperfusion volumes was assessed with Lin's test. Clinical outcome was compared between groups in patients who underwent successful EVT in the early and late time window.

RESULTS:

Mean core volume was higher and mean hypoperfusion volume was lower in method C than in methods A and B. In the early time window, methods A and B found fewer patients with a mismatch ratio ≤ 1.2 than method C (1/67 [1.5%] vs. 12/67 [17.9%], p = 0.0013). In the late time window, methods A and B found fewer patients with a mismatch ratio < 1.8 than method C (3/46 [6.5%] and 2/46 [4.3%] vs. 18/46 [39.1%], p ≤ 0.0002). More patients with functional independence at 3 months would not have been treated using method C versus methods A and B in the early (p = 0.0063) and late (p ≤ 0.011) time window.

CONCLUSIONS:

MRI software for DWI-PWI analysis may influence patients' selection before EVT and clinical outcome. KEY POINTS • Method C detects fewer patients with favourable mismatch profile. • Method C might underselect more patients with functional independence at 3 months. • Software used before thrombectomy may influence patients' outcome.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Isquemia Encefálica / Acidente Vascular Cerebral Tipo de estudo: Observational_studies Limite: Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Isquemia Encefálica / Acidente Vascular Cerebral Tipo de estudo: Observational_studies Limite: Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article