Your browser doesn't support javascript.
loading
Diagnostic Accuracy of Endobronchial Optical Coherence Tomography for the Microscopic Diagnosis of Usual Interstitial Pneumonia.
Nandy, Sreyankar; Raphaely, Rebecca A; Muniappan, Ashok; Shih, Angela; Roop, Benjamin W; Sharma, Amita; Keyes, Colleen M; Colby, Thomas V; Auchincloss, Hugh G; Gaissert, Henning A; Lanuti, Michael; Morse, Christopher R; Ott, Harald C; Wain, John C; Wright, Cameron D; Garcia-Moliner, Maria L; Smith, Maxwell L; VanderLaan, Paul A; Berigei, Sarita R; Mino-Kenudson, Mari; Horick, Nora K; Liang, Lloyd L; Davies, Diane L; Szabari, Margit V; Caravan, Peter; Medoff, Benjamin D; Tager, Andrew M; Suter, Melissa J; Hariri, Lida P.
Afiliação
  • Nandy S; Division of Pulmonary and Critical Care Medicine.
  • Raphaely RA; Wellman Center for Photomedicine.
  • Muniappan A; Harvard Medical School, Boston, Massachusetts.
  • Shih A; Division of Pulmonary and Critical Care Medicine.
  • Roop BW; Harvard Medical School, Boston, Massachusetts.
  • Sharma A; Division of Thoracic Surgery.
  • Keyes CM; Harvard Medical School, Boston, Massachusetts.
  • Colby TV; Department of Pathology.
  • Auchincloss HG; Harvard Medical School, Boston, Massachusetts.
  • Gaissert HA; Division of Pulmonary and Critical Care Medicine.
  • Lanuti M; Wellman Center for Photomedicine.
  • Morse CR; Department of Radiology, and.
  • Ott HC; Harvard Medical School, Boston, Massachusetts.
  • Wain JC; Division of Pulmonary and Critical Care Medicine.
  • Wright CD; Harvard Medical School, Boston, Massachusetts.
  • Garcia-Moliner ML; Department of Laboratory Medicine and Pathology, Mayo Clinic Arizona, Scottsdale, Arizona.
  • Smith ML; Division of Thoracic Surgery.
  • VanderLaan PA; Harvard Medical School, Boston, Massachusetts.
  • Berigei SR; Division of Thoracic Surgery.
  • Mino-Kenudson M; Harvard Medical School, Boston, Massachusetts.
  • Horick NK; Division of Thoracic Surgery.
  • Liang LL; Harvard Medical School, Boston, Massachusetts.
  • Davies DL; Division of Thoracic Surgery.
  • Szabari MV; Harvard Medical School, Boston, Massachusetts.
  • Caravan P; Division of Thoracic Surgery.
  • Medoff BD; Harvard Medical School, Boston, Massachusetts.
  • Tager AM; Division of Thoracic Surgery.
  • Suter MJ; Harvard Medical School, Boston, Massachusetts.
  • Hariri LP; St. Elizabeth's Medical Center, Boston, Massachusetts.
Am J Respir Crit Care Med ; 204(10): 1164-1179, 2021 11 15.
Article em En | MEDLINE | ID: mdl-34375171
ABSTRACT
Rationale Early, accurate diagnosis of interstitial lung disease (ILD) informs prognosis and therapy, especially in idiopathic pulmonary fibrosis (IPF). Current diagnostic methods are imperfect. High-resolution computed tomography has limited resolution, and surgical lung biopsy (SLB) carries risks of morbidity and mortality. Endobronchial optical coherence tomography (EB-OCT) is a low-risk, bronchoscope-compatible modality that images large lung volumes in vivo with microscopic resolution, including subpleural lung, and has the potential to improve the diagnostic accuracy of bronchoscopy for ILD diagnosis.

Objectives:

We performed a prospective diagnostic accuracy study of EB-OCT in patients with ILD with a low-confidence diagnosis undergoing SLB. The primary endpoints were EB-OCT sensitivity/specificity for diagnosis of the histopathologic pattern of usual interstitial pneumonia (UIP) and clinical IPF. The secondary endpoint was agreement between EB-OCT and SLB for diagnosis of the ILD fibrosis pattern.

Methods:

EB-OCT was performed immediately before SLB. The resulting EB-OCT images and histopathology were interpreted by blinded, independent pathologists. Clinical diagnosis was obtained from the treating pulmonologists after SLB, blinded to EB-OCT. Measurements and Main

Results:

We enrolled 31 patients, and 4 were excluded because of inconclusive histopathology or lack of EB-OCT data. Twenty-seven patients were included in the analysis (16 men, average age 65.0 yr) 12 were diagnosed with UIP and 15 with non-UIP ILD. Average FVC and DlCO were 75.3% (SD, 18.5) and 53.5% (SD, 16.4), respectively. Sensitivity and specificity of EB-OCT was 100% (95% confidence interval, 75.8-100.0%) and 100% (79.6-100%), respectively, for both histopathologic UIP and clinical diagnosis of IPF. There was high agreement between EB-OCT and histopathology for diagnosis of ILD fibrosis pattern (weighted κ 0.87 [0.72-1.0]).

Conclusions:

EB-OCT is a safe, accurate method for microscopic ILD diagnosis, as a complement to high-resolution computed tomography and an alternative to SLB.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Broncoscopia / Tomografia de Coerência Óptica / Fibrose Pulmonar Idiopática / Confiabilidade dos Dados Tipo de estudo: Diagnostic_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Broncoscopia / Tomografia de Coerência Óptica / Fibrose Pulmonar Idiopática / Confiabilidade dos Dados Tipo de estudo: Diagnostic_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2021 Tipo de documento: Article