Your browser doesn't support javascript.
loading
Feasibility and acceptability of monitoring personal air pollution exposure with sensors for asthma self-management.
Xie, Sherrie; Meeker, Jessica R; Perez, Luzmercy; Eriksen, Whitney; Localio, Anna; Park, Hami; Jen, Alicia; Goldstein, Madison; Temeng, Akua F; Morales, Sarai M; Christie, Colin; Greenblatt, Rebecca E; Barg, Frances K; Apter, Andrea J; Himes, Blanca E.
Afiliação
  • Xie S; Department, of Biostatistics, Epidemiology and Informatics, University of Pennsylvania, 402 Blockley Hall, 423 Guardian Drive, Philadelphia, PA, 19104, USA.
  • Meeker JR; Department, of Biostatistics, Epidemiology and Informatics, University of Pennsylvania, 402 Blockley Hall, 423 Guardian Drive, Philadelphia, PA, 19104, USA.
  • Perez L; Pulmonary, Allergy and Critical Care Division, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, 19104, USA.
  • Eriksen W; Mixed Methods Lab, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA.
  • Localio A; Pulmonary, Allergy and Critical Care Division, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, 19104, USA.
  • Park H; Pulmonary, Allergy and Critical Care Division, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, 19104, USA.
  • Jen A; Department, of Biostatistics, Epidemiology and Informatics, University of Pennsylvania, 402 Blockley Hall, 423 Guardian Drive, Philadelphia, PA, 19104, USA.
  • Goldstein M; Department, of Biostatistics, Epidemiology and Informatics, University of Pennsylvania, 402 Blockley Hall, 423 Guardian Drive, Philadelphia, PA, 19104, USA.
  • Temeng AF; Spelman College, Atlanta, GA, USA.
  • Morales SM; Florida State University, Tallahassee, FL, USA.
  • Christie C; Department, of Biostatistics, Epidemiology and Informatics, University of Pennsylvania, 402 Blockley Hall, 423 Guardian Drive, Philadelphia, PA, 19104, USA.
  • Greenblatt RE; Department, of Biostatistics, Epidemiology and Informatics, University of Pennsylvania, 402 Blockley Hall, 423 Guardian Drive, Philadelphia, PA, 19104, USA.
  • Barg FK; Department, of Biostatistics, Epidemiology and Informatics, University of Pennsylvania, 402 Blockley Hall, 423 Guardian Drive, Philadelphia, PA, 19104, USA.
  • Apter AJ; Mixed Methods Lab, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA.
  • Himes BE; Pulmonary, Allergy and Critical Care Division, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, 19104, USA.
Asthma Res Pract ; 7(1): 13, 2021 Sep 05.
Article em En | MEDLINE | ID: mdl-34482835
ABSTRACT

BACKGROUND:

Exposure to fine particulate matter (PM2.5) increases the risk of asthma exacerbations, and thus, monitoring personal exposure to PM2.5 may aid in disease self-management. Low-cost, portable air pollution sensors offer a convenient way to measure personal pollution exposure directly and may improve personalized monitoring compared with traditional methods that rely on stationary monitoring stations. We aimed to understand whether adults with asthma would be willing to use personal sensors to monitor their exposure to air pollution and to assess the feasibility of using sensors to measure real-time PM2.5 exposure.

METHODS:

We conducted semi-structured interviews with 15 adults with asthma to understand their willingness to use a personal pollution sensor and their privacy preferences with regard to sensor data. Student research assistants used HabitatMap AirBeam devices to take PM2.5 measurements at 1-s intervals while walking in Philadelphia neighborhoods in May-August 2018. AirBeam PM2.5 measurements were compared to concurrent measurements taken by three nearby regulatory monitors.

RESULTS:

All interview participants stated that they would use a personal air pollution sensor, though the consensus was that devices should be small (watch- or palm-sized) and light. Patients were generally unconcerned about privacy or sharing their GPS location, with only two stating they would not share their GPS location under any circumstances. PM2.5 measurements were taken using AirBeam sensors on 34 walks that extended through five Philadelphia neighborhoods. The range of sensor PM2.5 measurements was 0.6-97.6 µg/mL (mean 6.8 µg/mL), compared to 0-22.6 µg/mL (mean 9.0 µg/mL) measured by nearby regulatory monitors. Compared to stationary measurements, which were only available as 1-h integrated averages at discrete monitoring sites, sensor measurements permitted characterization of fine-scale fluctuations in PM2.5 levels over time and space.

CONCLUSIONS:

Patients were generally interested in using sensors to monitor their personal exposure to PM2.5 and willing to share personal sensor data with health care providers and researchers. Compared to traditional methods of personal exposure assessment, sensors captured personalized air quality information at higher spatiotemporal resolution. Improvements to currently available sensors, including more reliable Bluetooth connectivity, increased portability, and longer battery life would facilitate their use in a general patient population.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Tipo de estudo: Qualitative_research Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Tipo de estudo: Qualitative_research Idioma: En Ano de publicação: 2021 Tipo de documento: Article