Your browser doesn't support javascript.
loading
Stabilizing breathing pattern using local mechanical vibrations: comparison of deterministic and stochastic stimulations in rodent models of apnea of prematurity.
Zeldich, Dean; Bou Jawde, Samer; Herrmann, Jacob; Arnaout, Leen; Griffin, Meghan; Grunfeld, Noam; Zhang, Yu; Krishnan, Ramaswamy; Bartolák-Suki, Erzsébet; Suki, Béla.
Afiliação
  • Zeldich D; Department of Biomedical Engineering, Boston University, 44 Cummington Mall, Boston, MA 02215 USA.
  • Bou Jawde S; Department of Biomedical Engineering, Boston University, 44 Cummington Mall, Boston, MA 02215 USA.
  • Herrmann J; Department of Biomedical Engineering, Boston University, 44 Cummington Mall, Boston, MA 02215 USA.
  • Arnaout L; Department of Biomedical Engineering, Boston University, 44 Cummington Mall, Boston, MA 02215 USA.
  • Griffin M; Department of Biomedical Engineering, Boston University, 44 Cummington Mall, Boston, MA 02215 USA.
  • Grunfeld N; Department of Biomedical Engineering, Boston University, 44 Cummington Mall, Boston, MA 02215 USA.
  • Zhang Y; Department of Biomedical Engineering, Boston University, 44 Cummington Mall, Boston, MA 02215 USA.
  • Krishnan R; Department of Emergency Medicine, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA USA.
  • Bartolák-Suki E; Department of Biomedical Engineering, Boston University, 44 Cummington Mall, Boston, MA 02215 USA.
  • Suki B; Department of Biomedical Engineering, Boston University, 44 Cummington Mall, Boston, MA 02215 USA.
Biomed Eng Lett ; 11(4): 383-392, 2021 Nov.
Article em En | MEDLINE | ID: mdl-34490067
ABSTRACT
Mechanical stimulation has been shown to reduce apnea of prematurity (AOP), a major concern in preterm infants. Previous work suggested that the underlying mechanism is stochastic resonance, amplification of a subthreshold signal by stochastic stimulation. We hypothesized that the mechanism behind the reduction of apnea length may not be a solely stochastic phenomenon, and suggest that a purely deterministic, non-random mechanical stimulation could be equally as effective. Mice and rats were anesthetized, tracheostomized, and mechanically ventilated to halt spontaneous breathing. Two miniature motors controlled by a microcontroller were attached around the abdomen. Ventilation was paused, stimulations were applied, and the time to the rodent's first spontaneous breath (T) was measured. Six spectrally different signals were compared to one another and the no-stimulation control in mice. The most successful deterministic stimulation (D) at reducing apnea was then compared to a pseudo-random noise (PRN) signal of comparable amplitude and frequency. CO2%, CO2 stabilization time (Ts), O2 saturation (SpO2%), and T were also measured. D significantly reduced T compared to no stimulation for medium and high amplitudes. PRN also reduced T, without  a difference between D and PRN. Furthermore, both stimulations significantly reduced Ts with no significant differences between the respective stimulations. However, there was no effect of D or PRN on SpO2%. The lack of differences between D and PRN led to an additional series of experiment comparing the same D to a band-limited white noise (WN) signal in young rats. Both D and WN were shown to significantly reduce T, with D showing statistical superiority in reduction of apnea. We further speculate that both deterministic and stochastic mechanical stimulations induce some form of mechanotransduction which is responsible for their efficacy, and our findings suggest that mechanical stimulation may be effective in treating AOP. SUPPLEMENTARY INFORMATION The online version contains supplementary material available at 10.1007/s13534-021-00203-x.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Tipo de estudo: Prognostic_studies Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Tipo de estudo: Prognostic_studies Idioma: En Ano de publicação: 2021 Tipo de documento: Article