A Dual-emitting Two-dimensional Nickel-based Metal-organic Framework Nanosheets: Eu3+/Ag+ Functionalization Synthesis and Ratiometric Sensing in Aqueous Solution.
Shu, Yun; Dai, Tao; Ye, Qiuyu; Jin, Dangqin; Xu, Qin; Hu, Xiaoya.
Afiliação
  • Shu Y; School of Chemistry and Chemical Engineering, Yangzhou University, 225002, Yangzhou, China. shuyun1008@126.com.
  • Dai T; School of Chemistry and Chemical Engineering, Yangzhou University, 225002, Yangzhou, China.
  • Ye Q; School of Chemistry and Chemical Engineering, Yangzhou University, 225002, Yangzhou, China.
  • Jin D; Department of Chemical Engineering, Yangzhou Polytechnic Institute, 225127, Yangzhou, China.
  • Xu Q; School of Chemistry and Chemical Engineering, Yangzhou University, 225002, Yangzhou, China.
  • Hu X; School of Chemistry and Chemical Engineering, Yangzhou University, 225002, Yangzhou, China. xyhu@yzu.edu.cn.
J Fluoresc ; 31(6): 1947-1957, 2021 Nov.
Article em En | MEDLINE | ID: mdl-34546469
ABSTRACT
Using two-dimensional (2D) nickel-based metal organic framework (Ni-MOF) nanosheets as a matrix, Eu3+ and Ag+ were incorporated to synthesize Ag/Eu@Ni-MOF with double luminescence centers of Eu3+ ion (615 nm) and organic ligand (524 nm). And a ratiometric luminescence sensor is constructed based on Ag/Eu@Ni-MOF for sensitive detection of biothiols in aqueous solutions. The dual-emissive fluorescence properties can be tuned by changing the amounts of Ag+ ions doping. The results of temperature and pH effects on the fluorescence of Ag/Eu@Ni-MOF indicates that the Ag/Eu@Ni-MOF is a temperature-sensitive material and the fluorescence of Ag/Eu@Ni-MOF can keep stable over a wide pH range. Due to the binding of -SH in cysteine (Cys) and glutathione (GSH) with Ag+, the ligand luminescence was significantly inhibited by weakening the Ag + influence on the energy transfer process in the MOFs. Therefore, ratiometric fluorescent sensing of biomolecular thiols was realized based on the dual-emission Ag/Eu@Ni-MOF. More importantly, the fluorescence color change can be observed with naked eyes to realize visual detection. The ratiometric fluorescent sensor exhibits high performance for Cys and GSH detection with a wide linear range of 5-250 µM and a relatively low detection limit of 0.20 µM and 0.17 µM, respectively. Furthermore, the biothiols content in human serum was determined with satisfactory results. It proves the Ni-MOF nanosheets can be used as a stable matrix for construction luminescent MOFs for the first time, and validate the great potential of Ag/Eu@Ni-MOF as a ratiometric fluorescent probe for point-of-care testing (POCT) in disease diagnosis.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Prata / Compostos de Sulfidrila / Európio / Corantes Fluorescentes / Estruturas Metalorgânicas / Níquel Limite: Humans Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Prata / Compostos de Sulfidrila / Európio / Corantes Fluorescentes / Estruturas Metalorgânicas / Níquel Limite: Humans Idioma: En Ano de publicação: 2021 Tipo de documento: Article