Comparative Physicochemical Analysis among 1,4-Butanediol Diglycidyl Ether Cross-Linked Hyaluronic Acid Dermal Fillers.
Zerbinati, Nicola; Sommatis, Sabrina; Maccario, Cristina; Capillo, Maria Chiara; Grimaldi, Giulia; Alonci, Giuseppe; Rauso, Raffaele; Guida, Stefania; Mocchi, Roberto.
Afiliação
  • Zerbinati N; Department of Medicine and Surgery, University of Insubria, 21100 Varese, Italy.
  • Sommatis S; UB-CARE S.r.l.-Spin-off University of Pavia, 27100 Pavia, Italy.
  • Maccario C; UB-CARE S.r.l.-Spin-off University of Pavia, 27100 Pavia, Italy.
  • Capillo MC; UB-CARE S.r.l.-Spin-off University of Pavia, 27100 Pavia, Italy.
  • Grimaldi G; UB-CARE S.r.l.-Spin-off University of Pavia, 27100 Pavia, Italy.
  • Alonci G; Department of Research and Development, Matex Lab Switzerland SA, 1228 Geneve, Switzerland.
  • Rauso R; Maxillofacial Surgery Unit, University of Campania "Luigi Vanvitelli", 81100 Caserta, Italy.
  • Guida S; Dermatology Unit, Department of Surgical, Medical, Dental and Morphological Sciences Related to Transplant, Oncology and Regenerative Medicine, University of Modena and Reggio Emilia, 41124 Modena, Italy.
  • Mocchi R; UB-CARE S.r.l.-Spin-off University of Pavia, 27100 Pavia, Italy.
Gels ; 7(3)2021 Sep 11.
Article em En | MEDLINE | ID: mdl-34563025
ABSTRACT
(1)

Background:

Injectable hyaluronic acid (HA) dermal fillers are used in several chirurgical practices and in aesthetic medicine. HA filler stability can be enhanced through different cross-linking technologies; one of the most frequently cross-linker used is 1,4-butanediol diglycidyl ether (BDDE), also present in the HA-BDDE dermal filler family of the company Matex Lab S.p.A. (Brindisi, Italy). Our overview is focused on their characterization, drawing a correlation between matrix structure, rheological and physicochemical properties related to their cross-linking technologies. (2)

Methods:

Four different injectable HA hydrogels were characterized through optical microscopic examination and rheological behavior investigation. (3)

Results:

The cross-linked HA dermal fillers showed a fibrous "spiderweb-like" matrix structure and an elastic and solid-like profile. (4)

Conclusions:

The comparative analysis represents a preliminary characterization of these injectable medical devices in order to identify their best field of application.