Your browser doesn't support javascript.
loading
Anatomical human fitting of the BiVACOR total artificial heart.
Emmanuel, Sam; Jansz, Paul; McGiffin, David; Kure, Christina; Watson, Alasdair; Connellan, Mark; Granger, Emily; Iyer, Arjun; Timms, Daniel; Hayward, Christopher.
Afiliação
  • Emmanuel S; Heart Transplant Unit, St Vincent's Hospital, Sydney, New South Wales, Australia.
  • Jansz P; School of Medicine, University of New South Wales, Sydney, New South Wales, Australia.
  • McGiffin D; School of Medicine, University of Notre Dame, Sydney, New South Wales, Australia.
  • Kure C; Department of Medicine, Victor Chang Cardiac Research Institute, Sydney, New South Wales, Australia.
  • Watson A; Heart Transplant Unit, St Vincent's Hospital, Sydney, New South Wales, Australia.
  • Connellan M; School of Medicine, University of New South Wales, Sydney, New South Wales, Australia.
  • Granger E; School of Medicine, University of Notre Dame, Sydney, New South Wales, Australia.
  • Iyer A; Department of Medicine, Victor Chang Cardiac Research Institute, Sydney, New South Wales, Australia.
  • Timms D; Department of Cardiothoracic Surgery, The Alfred Hospital and Monash University, Melbourne, Victoria, Australia.
  • Hayward C; Department of Cardiothoracic Surgery, The Alfred Hospital and Monash University, Melbourne, Victoria, Australia.
Artif Organs ; 46(1): 50-56, 2022 Jan.
Article em En | MEDLINE | ID: mdl-34580890
BACKGROUND: BiVACOR is a novel total artificial heart (TAH) utilizing a single centrifugal magnetically levitated rotor with the ability to modulate pulsatile flow. The device has been successfully tested in a bovine model. We undertook a multicenter anatomical and virtual fitting study of the BiVACOR in patients undergoing heart transplantation. METHODS: 10 patients were recruited across two heart transplant centers. A sterilized 1:1 titanium model of the device was inserted into the patient's chest post heart explant, prior to implantation of the donor heart. Measurements were recorded in situ. The device was then removed. Following this, retrospective 3D reconstructions were created from computed tomography chest scans to simulate a virtual fitting. RESULTS: Mean age was 53 years (range 38-67). Mean BMI was 28 (range 20-37). Heart failure etiology was varied-with ischemic cardiomyopathy being the most common. Mean spine-to-sternum distance at the tenth thoracic vertebrae (T10) was 14 cm (range 11-18). Mean aorta to aortic Port distance was 0.2 cm (range 0-0.5). Mean pulmonary artery to pulmonary artery port distance was 4.2 cm (range 1-7). The device fitted suitably in all patients without gross distortion to the geometry between native vessel/chamber and port. CONCLUSIONS: This study described the anatomical and virtual fitting of the BiVACOR TAH. The device fit well within the chest cavities of all 10 patients, who represented a variety of body morphologies and heart failure etiology.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Coração / Coração Artificial Tipo de estudo: Clinical_trials Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Coração / Coração Artificial Tipo de estudo: Clinical_trials Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2022 Tipo de documento: Article