Your browser doesn't support javascript.
loading
[Finite element analysis of the graft stresses after anterior cruciate ligament reconstruction].
Ren, S; Shi, H J; Zhang, J H; Liu, Z L; Shao, J Y; Zhu, J X; Hu, X Q; Huang, H S; Ao, Y F.
Afiliação
  • Ren S; Department of Sports Medicine, Peking University Third Hospital; Institute of Sports Medicine of Peking University; Beijing Key Laboratory of Sports Injuries, Beijing 100191, China.
  • Shi HJ; Department of Sports Medicine, Peking University Third Hospital; Institute of Sports Medicine of Peking University; Beijing Key Laboratory of Sports Injuries, Beijing 100191, China.
  • Zhang JH; Department of Sports Medicine, Peking University Third Hospital; Institute of Sports Medicine of Peking University; Beijing Key Laboratory of Sports Injuries, Beijing 100191, China.
  • Liu ZL; Department of Sports Medicine, Peking University Third Hospital; Institute of Sports Medicine of Peking University; Beijing Key Laboratory of Sports Injuries, Beijing 100191, China.
  • Shao JY; Department of Sports Medicine, Peking University Third Hospital; Institute of Sports Medicine of Peking University; Beijing Key Laboratory of Sports Injuries, Beijing 100191, China.
  • Zhu JX; Department of Sports Medicine, Peking University Third Hospital; Institute of Sports Medicine of Peking University; Beijing Key Laboratory of Sports Injuries, Beijing 100191, China.
  • Hu XQ; Department of Sports Medicine, Peking University Third Hospital; Institute of Sports Medicine of Peking University; Beijing Key Laboratory of Sports Injuries, Beijing 100191, China.
  • Huang HS; Department of Sports Medicine, Peking University Third Hospital; Institute of Sports Medicine of Peking University; Beijing Key Laboratory of Sports Injuries, Beijing 100191, China.
  • Ao YF; Department of Sports Medicine, Peking University Third Hospital; Institute of Sports Medicine of Peking University; Beijing Key Laboratory of Sports Injuries, Beijing 100191, China.
Beijing Da Xue Xue Bao Yi Xue Ban ; 53(5): 865-870, 2021 Oct 18.
Article em Zh | MEDLINE | ID: mdl-34650286
ABSTRACT

OBJECTIVE:

To explore the stress distribution characteristics of the graft after anterior cruciate ligament (ACL) reconstruction, so as to provide theoretical reference for the surgical plan of ACL reconstruction.

METHODS:

Based on 3D MRI and CT images, finite element models of the uninjured knee joint and knee joint after ACL reconstruction were established in this study. The uninjured knee model included femur, tibia, fibula, medial collateral ligament, lateral collateral ligament, ACL and posterior cruciate ligament. The ACL reconstruction knee model included femur, tibia, fibula, medial collateral ligament, lateral collateral ligament, ACL graft and posterior cruciate ligament. Linear elastic material properties were used for both the uninjured and ACL reconstruction models. The elastic modulus of bone tissue was set as 17 GPa and Poisson' s ratio was 0.36. The material properties of ligament tissue and graft were set as elastic modulus 390 MPa and Poisson's ratio 0.4. The femur was fixed as the boundary condition, and the tibia anterior tension of 134 N was applied as the loading condition. The stress states of the ACL of the intact joint and the ACL graft after reconstruction were solved and analyzed, including tension, pressure, shear force and von Mises stress.

RESULTS:

The maximum compressive stress (6.34 MPa), von Mises stress (5.9 MPa) and shear stress (1.83 MPa) of the reconstructed ACL graft were all at the anterior femoral end. It was consistent with the position of maximum compressive stress (8.77 MPa), von Mises stress (8.88 MPa) and shear stress (3.44 MPa) in the ACL of the intact knee joint. The maximum tensile stress of the graft also appeared at the femoral end, but at the posterior side, which was consistent with the position of the maximum tensile stress of ACL of the uninjured knee joint. More-over, the maximum tensile stress of the graft was only 0.88 MPa, which was less than 2.56 MPa of ACL of the uninjured knee joint.

CONCLUSION:

The maximum compressive stress, von Mises stress and shear stress of the ACL graft are located in the anterior femoral end, and the maximum tensile stress is located in the posterior femoral end, which is consistent with the position of the maximum tensile stress of the ACL of the uninjured knee joint. The anterior part of ACL and the graft bore higher stresses than the posterior part, which is consistent with the biomechanical characteristics of ACL.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Reconstrução do Ligamento Cruzado Anterior / Lesões do Ligamento Cruzado Anterior Tipo de estudo: Prognostic_studies Limite: Humans Idioma: Zh Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Reconstrução do Ligamento Cruzado Anterior / Lesões do Ligamento Cruzado Anterior Tipo de estudo: Prognostic_studies Limite: Humans Idioma: Zh Ano de publicação: 2021 Tipo de documento: Article