Your browser doesn't support javascript.
loading
Multiple myeloma: Detection of free monoclonal light chains by modified immunofixation electrophoresis with antisera against free light chains.
Wilhite, Dorian; Arfa, Ahmed; Cotter, Thomas; Savage, Natasha M; Bollag, Roni J; Singh, Gurmukh.
Afiliação
  • Wilhite D; Department of Pathology, Medical College of Georgia at Augusta University, 1120 15th Street, BI 2008A, Augusta, GA, 30912, USA.
  • Arfa A; Department of Pathology, Medical College of Georgia at Augusta University, 1120 15th Street, BI 2008A, Augusta, GA, 30912, USA.
  • Cotter T; Department of Pathology, Medical College of Georgia at Augusta University, 1120 15th Street, BI 2008A, Augusta, GA, 30912, USA.
  • Savage NM; Department of Pathology, Medical College of Georgia at Augusta University, 1120 15th Street, BI 2008A, Augusta, GA, 30912, USA.
  • Bollag RJ; Department of Pathology, Medical College of Georgia at Augusta University, 1120 15th Street, BI 2008A, Augusta, GA, 30912, USA.
  • Singh G; Department of Pathology, Medical College of Georgia at Augusta University, 1120 15th Street, BI 2008A, Augusta, GA, 30912, USA.
Pract Lab Med ; 27: e00256, 2021 Nov.
Article em En | MEDLINE | ID: mdl-34703870
ABSTRACT

INTRODUCTION:

Neoplastic monoclonal gammopathies are frequently associated with production of excess free monoclonal light chains. A sensitive method for detecting free monoclonal light chains in serum could provide a marker for residual/minimal residual disease and as an adjunct to serum protein electrophoresis to serve as a screening method for monoclonal gammopathies.

METHODS:

Conventional serum immunofixation electrophoresis was modified by applying undiluted serum samples, and staining for serum free light chains with antisera specific to free light chains. Washing/blotting of gels was enhanced to remove residual proteins that did not bind to the antibodies including intact monoclonal immunoglobulins. Results from this modified immunofixation electrophoresis were compared with results from commercially available MASS-FIX/MALDI assay.

RESULTS:

Monoclonal free kappa light chains could be detected to a concentration of about 1.78 mg/L and monoclonal free lambda light chains to a concentration of about 1.15 mg/L without the need for special equipment. Comparison of these thresholds with parallel results from a commercially available MASS-FIX/MALDI assay revealed the modified electrophoretic method to be more sensitive in the context of free monoclonal light chains.

CONCLUSIONS:

Modified serum immunofixation electrophoresis has been shown to detect low levels of monoclonal free light chains at a sensitivity suitable for the method to be used in detecting minimal residual disease, and potentially in a screening assay for monoclonal gammopathies. The disparity in the results with commercially available MASS-FIX/MALDI assay is postulated to be due to limited repertoire of reactivity of nanobodies of camelid origin.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Ano de publicação: 2021 Tipo de documento: Article