Your browser doesn't support javascript.
loading
Ultrasensitive photoelectrochemical microcystin-LR immunosensor using carboxyl-functionalized graphene oxide enhanced gold nanoclusters for signal amplification.
Fan, Liang; Xiao, Gang; Wang, Mingliang; Zhao, Shuang; Yang, Qiaochun; Cheng, Linyang; Huang, Jinhui Jeanne; Yue, Zhao.
Afiliação
  • Fan L; College of Environmental Science and Engineering/Sino-Canada R&D Centre on Water and Environmental Safety, Nankai University, Tianjin, 300350, China.
  • Xiao G; Department of Microelectronics, Nankai University, Tianjin, 300350, China.
  • Wang M; Department of Microelectronics, Nankai University, Tianjin, 300350, China.
  • Zhao S; School of Information Science and Engineering, Yanshan University, Qinhuangdao, 066004, China.
  • Yang Q; Department of Microelectronics, Nankai University, Tianjin, 300350, China.
  • Cheng L; Department of Microelectronics, Nankai University, Tianjin, 300350, China.
  • Huang JJ; College of Environmental Science and Engineering/Sino-Canada R&D Centre on Water and Environmental Safety, Nankai University, Tianjin, 300350, China. Electronic address: huangj@nankai.edu.cn.
  • Yue Z; Department of Microelectronics, Nankai University, Tianjin, 300350, China; Tianjin Key Laboratory of Optoelectronic Sensor and Sensing Network Technology, Tianjin, 300350, China. Electronic address: yuezhao@nankai.edu.cn.
Anal Chim Acta ; 1185: 339078, 2021 Nov 15.
Article em En | MEDLINE | ID: mdl-34711309
ABSTRACT
An ultrasensitive photoelectrochemical (PEC) immunosensor based on gold nanoclusters (AuNCs) with 11-mercaptoundecanoic acid (MUA) ligands was fabricated for determination of microcystin-LR (MC-LR). The PEC immunosensor was developed by loading the monoclonal MC-LR antibody (Ab) to the MUA-AuNCs modified gold electrodes. After different measurement conditions being optimized, silver nanoparticles (AgNPs), gold nanorods (AuNRs), graphene oxide (GO) and carboxyl-functionalized graphene oxide (cGO) were introduced into MUA-AuNCs to enhance the sensing properties. The experimental result revealed that the sensitivity of PEC immunosensors was enhanced by both their photoelectrochemical properties and antibody loading properties with dependent relationship, which was different from the enhancement strategy of PEC sensors based on redox reactions. Among different hybrid nanocomposites, MUA-AuNCs/cGO not only improved the photoelectrochemical properties, but also loaded more antibodies for sensing, which resulted in best sensing performance. Thus, a universal method was proposed to enhance the sensing performance of PEC immunosensors based on impedance changes. Finally, MUA-AuNCs/cGO based PEC immunosensors exhibited a wide linear range of 0.001 nM-1000 nM with low detection limit of 0.011 pM (S/N = 3) for MC-LR determination. Meanwhile, the designed PEC immunosensors showed high selectivity, reproducibility and specificity, which provided the promising applications in aquatic environment.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Nanopartículas Metálicas / Grafite Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Nanopartículas Metálicas / Grafite Idioma: En Ano de publicação: 2021 Tipo de documento: Article