Your browser doesn't support javascript.
loading
Successful application of closed loop stimulation pacemakers with remote monitoring in 3 miniature donkeys with syncope.
De Lange, Lisa; Van Steenkiste, Glenn; Vernemmen, Ingrid; Vera, Lisse; Cromheeke, Kristel M C; Walser, Ulla; Meert, Hans; Decloedt, Annelies; van Loon, Gunther.
Afiliação
  • De Lange L; Equine Cardioteam, Department of Large Animal Internal Medicine, Faculty of Veterinary Medicine, Merelbeke, Belgium.
  • Van Steenkiste G; Equine Cardioteam, Department of Large Animal Internal Medicine, Faculty of Veterinary Medicine, Merelbeke, Belgium.
  • Vernemmen I; Equine Cardioteam, Department of Large Animal Internal Medicine, Faculty of Veterinary Medicine, Merelbeke, Belgium.
  • Vera L; Equine Cardioteam, Department of Large Animal Internal Medicine, Faculty of Veterinary Medicine, Merelbeke, Belgium.
  • Cromheeke KMC; Anegria, VZW Donkey Sanctuary, Sint-Gillis-Waas, Belgium.
  • Walser U; Biotronik Belgium, Vilvoorde, Belgium.
  • Meert H; Biotronik SE & Co. KG, Berlin, Germany.
  • Decloedt A; Biotronik Belgium, Vilvoorde, Belgium.
  • van Loon G; Biotronik SE & Co. KG, Berlin, Germany.
J Vet Intern Med ; 35(6): 2920-2925, 2021 Nov.
Article em En | MEDLINE | ID: mdl-34741540
ABSTRACT
Rate-adaptive single chamber pacemakers with accelerometer, closed loop stimulation (CLS), and remote monitoring functionality (Eluna 8 SR-T, Biotronik, SE & Co, Germany) were implanted in 3 miniature donkeys with third-degree atrioventricular block and syncope. After recovery, different pacemaker programming modes were tested at rest, during stress without physical exercise and during physical exercise. Pacing rates were compared to actual atrial rates and showed that CLS functionality allowed physiological heart rate adaptation. A transmitter installed in the stable provided wireless connection of the pacemaker to the internet. Home monitoring was activated which performed daily wireless transmission of pacemaker functional measurements to an online server allowing diagnosis of pathological arrhythmias and pacemaker malfunction from a distance. Closed loop stimulation and remote monitoring functionality resulted in nearly physiological rate adaptation and allowed remote "from-the-stable" patient follow-up.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Marca-Passo Artificial / Bloqueio Atrioventricular Tipo de estudo: Diagnostic_studies Limite: Animals Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Marca-Passo Artificial / Bloqueio Atrioventricular Tipo de estudo: Diagnostic_studies Limite: Animals Idioma: En Ano de publicação: 2021 Tipo de documento: Article