Implementation of more sensitive cardiac troponin T assay in a state-wide health service.
Khan, Ehsan; Lambrakis, Kristina; Nazir, Sheraz A; Chuang, Anthony; Halabi, Amera; Tiver, Kathryn; Briffa, Tom; Cullen, Louise A; Horsfall, Matthew; French, John K; Sun, Benjamin C; Chew, Derek P.
Afiliação
  • Khan E; College of Medicine & Public Health, Flinders University of South Australia, Adelaide, Australia; South Australian Department of Health, Adelaide, Australia.
  • Lambrakis K; College of Medicine & Public Health, Flinders University of South Australia, Adelaide, Australia; South Australian Department of Health, Adelaide, Australia.
  • Nazir SA; Department of Cardiology, University Hospitals of Coventry & Warwickshire NHS Trust, Coventry, CV2 2DX, UK; Department of Cardiovascular Sciences, University of Leicester and the National Institute for Health for Research (NIHR) Leicester Cardiovascular Biomedical Research Centre, Glenfield Hosp
  • Chuang A; College of Medicine & Public Health, Flinders University of South Australia, Adelaide, Australia; South Australian Department of Health, Adelaide, Australia.
  • Halabi A; College of Medicine & Public Health, Flinders University of South Australia, Adelaide, Australia; South Australian Department of Health, Adelaide, Australia.
  • Tiver K; College of Medicine & Public Health, Flinders University of South Australia, Adelaide, Australia; South Australian Department of Health, Adelaide, Australia.
  • Briffa T; School of Population and Global Health, University of Western Australia, Perth, Australia.
  • Cullen LA; Emergency and Trauma Centre, Royal Brisbane and Women's Hospital, Brisbane, Australia; School of Public Health, Queensland University of Technology, Brisbane, Australia; School of Medicine, University of Queensland, Brisbane, Australia.
  • Horsfall M; College of Medicine & Public Health, Flinders University of South Australia, Adelaide, Australia; South Australian Department of Health, Adelaide, Australia.
  • French JK; Department of Cardiology, Liverpool Hospital, University of New South Wales, Sydney, Australia.
  • Sun BC; Center for Policy Research-Emergency Medicine, Department of Emergency Medicine, Oregon Health and Science University, Portland, OR, United States of America.
  • Chew DP; College of Medicine & Public Health, Flinders University of South Australia, Adelaide, Australia; South Australian Health and Medical Research Institute, Adelaide, Australia; South Australian Department of Health, Adelaide, Australia. Electronic address: derek.chew@flinders.edu.au.
Int J Cardiol ; 347: 66-72, 2022 Jan 15.
Article em En | MEDLINE | ID: mdl-34774641
ABSTRACT

AIMS:

Explore the impact of deploying high-sensitivity (hs) cardiac troponin T (cTnT) assay across a state-wide health service. METHODS AND

RESULTS:

Presentations to emergency departments of six tertiary hospitals between January 2008 and August 2019 were included; standard cTnT assay was superseded by hs-cTnT in June 2011 without changing the reference range (≥30 ng/L reported as elevated), despite cTnT level of 30 ng/L being equivalent to ∼44 ng/L with hs-cTnT. Clinical outcomes were captured using state-wide linked health records. Interrupted time series analyses were used adjusted for seasonality and multiple co-morbidities using propensity score matching allowing for correlation within hospitals. In total, 614,847 presentations had ≥1 troponin measurement. Clinical ordering of troponin decreased throughout the study with no increase in elevated measurements amongst those tested with hs-cTnT. Small but statistically significant changes in index myocardial infarction (MI) diagnosis (-0.36%/year, 95%CI [confidence interval]-0.48, -0.24,p < 0.001) and invasive coronary angiography (0.12%/year,95%CI0, 0.24,p = 0.02) were seen, with no impact on death/MI at 30 days or 3-year survival in episodes of care (EOCs) with elevated cTnT after hs-cTnT implementation. Length of stay (LOS) was shorter among those with an elevated hs-cTnT (-4.44 h/year, 95%CI-5.27, -3.60, p < 0.001). Non-elevated cTnT EOCs demonstrated shorter total LOS and improved 3-year survival (adjusted hazard ratio0.90, 95%CI0.83, 0.97,p = 0.008) although death/MI at 30 days was unchanged using hs-cTnT.

CONCLUSION:

Widespread implementation of hs-cTnT without altering clinical thresholds reported to clinicians provided significantly shorter LOS without a clinically significant impact on clinical outcomes. A safer cohort with non-elevated cTnT was identified by hs-cTnT compared to the standard cTnT assay.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Troponina T / Infarto do Miocárdio Tipo de estudo: Diagnostic_studies / Etiology_studies / Incidence_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Troponina T / Infarto do Miocárdio Tipo de estudo: Diagnostic_studies / Etiology_studies / Incidence_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article