Your browser doesn't support javascript.
loading
k-t accelerated multi-VENC 4D flow MRI improves vortex assessment in pulmonary hypertension.
Kroeger, Jan Robert; Stackl, Marc; Weiss, Kilian; Baeßler, Bettina; Gerhardt, Felix; Rosenkranz, Stephan; Maintz, David; Giese, Daniel; Bunck, Alexander Christian.
Afiliação
  • Kroeger JR; Department of Radiology, University of Cologne, Faculty of Medicine and University Hospital Cologne, Cologne, Germany; Department of Radiology, Neuroradiology and Nuclear Medicine, Johannes Wesling University Hospital, Ruhr University Bochum, Germany. Electronic address: janrobert.kroeger@muehlenkre
  • Stackl M; Department of Radiology, University of Cologne, Faculty of Medicine and University Hospital Cologne, Cologne, Germany.
  • Weiss K; Department of Radiology, University of Cologne, Faculty of Medicine and University Hospital Cologne, Cologne, Germany; Philips GmbH, Hamburg, Germany.
  • Baeßler B; Department of Radiology, University of Cologne, Faculty of Medicine and University Hospital Cologne, Cologne, Germany; Institute of Diagnostic and Interventional Radiology, University Hospital Zurich und Universität Zürich, Zurich, Switzerland.
  • Gerhardt F; Department of Cardiology, University of Cologne, Faculty of Medicine and University Hospital Cologne, Cologne, Germany.
  • Rosenkranz S; Department of Cardiology, University of Cologne, Faculty of Medicine and University Hospital Cologne, Cologne, Germany.
  • Maintz D; Department of Radiology, University of Cologne, Faculty of Medicine and University Hospital Cologne, Cologne, Germany.
  • Giese D; Department of Radiology, University of Cologne, Faculty of Medicine and University Hospital Cologne, Cologne, Germany.
  • Bunck AC; Department of Radiology, University of Cologne, Faculty of Medicine and University Hospital Cologne, Cologne, Germany.
Eur J Radiol ; 145: 110035, 2021 Dec.
Article em En | MEDLINE | ID: mdl-34801875
ABSTRACT

BACKGROUND:

4D flow imaging can be used to evaluate vortex formation in the pulmonary artery seen in patients with pulmonary hypertension. We evaluated if a k-t accelerated multi-VENC (velocity encoding) 4D flow acquisition improves image quality, inter-reader agreement and correlation with hemodynamic parameters.

METHODS:

A total of 14 patients with pulmonary hypertension (5 females, 9 males; mean age 61 ± 16 years) underwent 4D flow MRI (magnetic resonance imaging) and right heart catheterization. In addition to that, 13 healthy volunteers (2 females, 11 males, mean age 33 ± 12 years) also underwent 4D flow MRI. Multi- and single-VENC datasets were reconstructed and evaluated for vortex formation and vortex duration by two blinded readers and image quality was rated on a 5-point scale.

RESULTS:

Both readers rated image quality as significantly higher on multi-VENC datasets (3.96 ± 0.71 vs. 2.56 ± 0.93, p < 0.001; 4.70 ± 0.61 vs. 4.07 ± 0.92, p = 0.003). Inter-reader correlation for vortex duration quantification was higher on multi-VENC datasets compared to single-VENC datasets (r = 0.63 vs. r = 0.44). No significant correlation was found between vortex duration and mean pulmonary artery pressure in patients with PH.

CONCLUSION:

Multi-VENC 4D flow MRI significantly improves image quality and inter-reader agreement for the evaluation of vortex formation in the pulmonary artery.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Hipertensão Pulmonar Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Hipertensão Pulmonar Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2021 Tipo de documento: Article