Traceable Nanoscale Measurements of High Dielectric Constant by Scanning Microwave Microscopy.
Richert, Damien; Morán-Meza, José; Kaja, Khaled; Delvallée, Alexandra; Allal, Djamel; Gautier, Brice; Piquemal, François.
Afiliação
  • Richert D; Laboratoire National de Métrologie et d'Essais (LNE), 78197 Trappes, France.
  • Morán-Meza J; Laboratoire National de Métrologie et d'Essais (LNE), 78197 Trappes, France.
  • Kaja K; Laboratoire National de Métrologie et d'Essais (LNE), 78197 Trappes, France.
  • Delvallée A; Laboratoire National de Métrologie et d'Essais (LNE), 78197 Trappes, France.
  • Allal D; Laboratoire National de Métrologie et d'Essais (LNE), 78197 Trappes, France.
  • Gautier B; Institut National des Sciences Appliquées de Lyon, 69100 Villeurbanne, France.
  • Piquemal F; Institut des Nanotechnologies de Lyon, 69100 Villeurbanne, France.
Nanomaterials (Basel) ; 11(11)2021 Nov 17.
Article em En | MEDLINE | ID: mdl-34835868
The importance of high dielectric constant materials in the development of high frequency nano-electronic devices is undeniable. Their polarization properties are directly dependent on the value of their relative permittivity. We report here on the nanoscale metrological quantification of the dielectric constants of two high-κ materials, lead zirconate titanate (PZT) and lead magnesium niobate-lead titanate (PMN-PT), in the GHz range using scanning microwave microscopy (SMM). We demonstrate the importance of the capacitance calibration procedure and dimensional measurements on the weight of the combined relative uncertainties. A novel approach is proposed to correct lateral dimension measurements of micro-capacitive structures using the microwave electrical signatures, especially for rough surfaces of high-κ materials. A new analytical expression is also given for the capacitance calculations, taking into account the contribution of fringing electric fields. We determine the dielectric constant values εPZT = 445 and εPMN-PT = 641 at the frequency around 3.6 GHz, with combined relative uncertainties of 3.5% and 6.9% for PZT and PMN-PT, respectively. This work provides a general description of the metrological path for a quantified measurement of high dielectric constants with well-controlled low uncertainty levels.