Your browser doesn't support javascript.
loading
Exendin-4-Conjugated Manganese Magnetism-Engineered Iron Oxide Nanoparticles as a Potential Magnetic Resonance Imaging Contrast Agent for Tracking Transplanted ß-Cells.
Juang, Jyuhn-Huarng; Shen, Chia-Rui; Wang, Jiun-Jie; Wu, Shu-Ting; Lin, Sung-Han; Chen, Chen-Yi; Kao, Chen-Wei; Chen, Chen-Ling; Tsai, Zei-Tsan; Wang, Yun-Ming.
Afiliação
  • Juang JH; Division of Endocrinology and Metabolism, Department of Internal Medicine and Center for Tissue Engineering, Chang Gung Memorial Hospital, Taoyuan 33305, Taiwan.
  • Shen CR; Department of Medicine, College of Medicine, Chang Gung University, Taoyuan 33302, Taiwan.
  • Wang JJ; Department of Medical Biotechnology and Laboratory Science, College of Medicine, Chang Gung University, Taoyuan 33302, Taiwan.
  • Wu ST; Department of Ophthalmology, Chang Gung Memorial Hospital, Taoyuan 33305, Taiwan.
  • Lin SH; Department of Medical Imaging and Radiological Sciences, College of Medicine, Chang Gung University, Taoyuan 33302, Taiwan.
  • Chen CY; Department of Diagnostic Radiology, Chang Gung Memorial Hospital, Keelung 20401, Taiwan.
  • Kao CW; Department of Medical Biotechnology and Laboratory Science, College of Medicine, Chang Gung University, Taoyuan 33302, Taiwan.
  • Chen CL; Department of Medical Imaging and Radiological Sciences, College of Medicine, Chang Gung University, Taoyuan 33302, Taiwan.
  • Tsai ZT; Division of Endocrinology and Metabolism, Department of Internal Medicine and Center for Tissue Engineering, Chang Gung Memorial Hospital, Taoyuan 33305, Taiwan.
  • Wang YM; Division of Endocrinology and Metabolism, Department of Internal Medicine and Center for Tissue Engineering, Chang Gung Memorial Hospital, Taoyuan 33305, Taiwan.
Nanomaterials (Basel) ; 11(11)2021 Nov 21.
Article em En | MEDLINE | ID: mdl-34835906
ABSTRACT
To specifically detect and trace transplanted islet ß-cells by magnetic resonance imaging (MRI), we conjugated manganese magnetism-engineered iron oxide nanoparticles (MnMEIO NPs) with exendin-4 (Ex4) which specifically binds glucagon-like peptide-1 receptors on the surface of ß-cells. The size distribution of MnMEIO and MnMEIO-Ex4 NPs were 67.8 ± 1.3 and 70.2 ± 2.3 nm and zeta potential 33.3 ± 0.5 and 0.6 ± 0.1 mV, respectively. MnMEIO and MnMEIO-Ex4 NPs with iron content ≤ 40 µg/mL did not affect MIN6 ß-cell viability and insulin secretion. Positive iron staining was found in MIN6 ß-cells loaded with MnMEIO-Ex4 NPs but not in those with MnMEIO NPs. A transmission electron microscope confirmed MnMEIO-Ex4 NPs were distributed in the cytoplasm of MIN6. In vitro MR images revealed a loss of signal intensity in MIN6 ß-cells labeled with MnMEIO-Ex4 NPs but not with MnMEIO NPs. After transplantation of islets labeled with MnMEIO-Ex4, the graft under kidney capsule could be visualized on MRI as persistent hypointense areas up to 17 weeks. Moreover, histology of the islet graft showed positive staining for insulin, glucagon and iron. Our results indicate MnMEIO-Ex4 NPs are safe and effective for the detection and long-term monitoring of transplanted ß-cells by MRI.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2021 Tipo de documento: Article