Your browser doesn't support javascript.
loading
Developing a Biorelevant Dissolution Method for an Extrudable Core System (ECS) Osmotic Tablet.
Chen, Raymond; Blanchard, Andrew; Kushner, Joseph; Harrington, Brent; Liu, Jia; DeMatteo, Vincent.
Afiliação
  • Chen R; Analytical Research and Development, Worldwide Research, Development and Medical, Pfizer Inc., Groton, Connecticut, 06340, USA. raymond.chen@pfizer.com.
  • Blanchard A; Analytical Research and Development, Worldwide Research, Development and Medical, Pfizer Inc., Groton, Connecticut, 06340, USA.
  • Kushner J; Drug Product Design, Worldwide Research, Development and Medical, Pfizer Inc., Groton, Connecticut, 06340, USA.
  • Harrington B; Pharmaceutical Sciences & PGS Statistics, Analytical Research and Development, Worldwide Research, Development and Medical, Pfizer Inc., Groton, Connecticut, 06340, USA.
  • Liu J; Pharmaceutical Sciences & PGS Statistics, Analytical Research and Development, Worldwide Research, Development and Medical, Pfizer Inc., Groton, Connecticut, 06340, USA.
  • DeMatteo V; Analytical Research and Development, Worldwide Research, Development and Medical, Pfizer Inc., Groton, Connecticut, 06340, USA.
AAPS PharmSciTech ; 23(1): 5, 2021 Nov 30.
Article em En | MEDLINE | ID: mdl-34850297
The objective of this work is to develop a biorelevant dissolution method to support the clinical study for In Vitro In Vivo Correlation (IVIVC) of the first commercially approved single-layer extrudable core system (ECS) osmotic tablet - the 11 mg tofacitinib modified-release tablet. The dissolution conditions were selected through analysis of experimental work including several designed experiments (DoE). The Apparatus 2 (paddles) was selected over the Apparatus 1 (baskets) to minimize the dissolution test variability. The paddle speed was kept at 50 rpm to be conservative and because higher paddle speed did not offer statistically significant improvement in dissolution test variability. The buffer of 50 mM potassium phosphate at pH 6.8 was selected over other buffers at lower or acid pH as the in vivo drug release is expected to occur in the small intestinal region, where the pH is approximately neutral. Finally, the statistically designed experiments proved that use of the Japanese basket sinkers was effective in reducing dissolution variability and eliminating the artificial shift in dissolution profile caused by final pink color-coated tablets sticking to the dissolution vessel. Discriminatory power of the method was verified and the method was validated per ICH and FDA guidelines. Since a Level A IVIVC is established from the analysis of the results of both in vivo clinical study and in vitro dissolution testing, the method is proven to be biorelevant. It also serves a suitable quality control dissolution method.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Química Farmacêutica Tipo de estudo: Guideline Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Química Farmacêutica Tipo de estudo: Guideline Idioma: En Ano de publicação: 2021 Tipo de documento: Article