Your browser doesn't support javascript.
loading
Efficiency of dual-energy computed tomography enterography in the diagnosis of Crohn's disease.
Chen, Jinghao; Zhou, Jie; Yang, Jushun; Cong, Ruochen; Sun, Jinjie; Xiao, Jing; Shi, Jianhua; He, Bosheng.
Afiliação
  • Chen J; Department of Radiology, Affiliated Hospital 2 of Nantong University, Nantong City, 226001, Jiangsu Province, China.
  • Zhou J; Department of Radiology, Affiliated Hospital 2 of Nantong University, Nantong City, 226001, Jiangsu Province, China.
  • Yang J; Department of Radiology, Changzhou Hospital of Traditional Chinese Medicine, Changzhou City, 213000, Jiangsu Province, China.
  • Cong R; Department of Radiology, Affiliated Hospital 2 of Nantong University, Nantong City, 226001, Jiangsu Province, China.
  • Sun J; Department of Radiology, Affiliated Hospital 2 of Nantong University, Nantong City, 226001, Jiangsu Province, China.
  • Xiao J; Gastrointestinal Surgery, Affiliated Hospital 2 of Nantong University, Nantong City, 226001, Jiangsu Province, China.
  • Shi J; Department of Epidemiology and Medical Statistics, School of Public Health, Nantong University, Nantong City, 226019, Jiangsu Province, China.
  • He B; Department of Biochemistry, Nantong University Medical School, Nantong City, 226019, Jiangsu Province, China.
BMC Med Imaging ; 21(1): 185, 2021 12 03.
Article em En | MEDLINE | ID: mdl-34861843
ABSTRACT

BACKGROUND:

This retrospective study aimed to investigate the usefulness of the optimized kiloelectron volt (keV) for virtual monoenergetic imaging (VMI) combined with iodine map in dual-energy computed tomography enterography (DECTE) in the diagnosis of Crohn's disease (CD).

METHODS:

Seventy-two patients (mean age 41.89 ± 17.28 years) with negative computed tomography enterography (CTE) were enrolled for investigating the optimized VMI keV in DECTE by comparing subjective and objective parameters of VMIs that were reconstructed from 40 to 90 keV. Moreover, 68 patients (38.27 ± 15.10 years; 35 normal and 33 CD) were included for evaluating the diagnostic efficacy of DECTE iodine map at the optimized VMI energy level and routine CTE for CD and active CD. Statistical analysis for all data was conducted.

RESULTS:

Objective and subjective imaging evaluations showed the best results at 60 keV for VMIs. The CT values of the normal group, active subgroup, and CD group during the small intestinal phase at routine 120 kVp or 60 keV VMI had significant differences. The diagnostic efficacy of an iodine map was the best when NIC = 4% or fat value = 45.8% for CD, whereas NIC < 0.35 or the fat value < 0.38 for active CD. The combined routine CTE and optimized VMI improved the diagnostic efficacy (P < 0.001).

CONCLUSIONS:

VMI at 60 keV provided the best imaging quality on DECTE. NIC and fat value provided important basis for active CD evaluation. Routine CTE combined with VMI at 60 keV improved the diagnostic efficiency for CD.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Doença de Crohn / Tomografia Computadorizada por Raios X Tipo de estudo: Diagnostic_studies / Observational_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Doença de Crohn / Tomografia Computadorizada por Raios X Tipo de estudo: Diagnostic_studies / Observational_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2021 Tipo de documento: Article