Your browser doesn't support javascript.
loading
COVID-19 diagnosis by SARS-CoV-2 Spike protein detection in saliva using an ultrasensitive magneto-assay based on disposable electrochemical sensor.
Nascimento, Evair D; Fonseca, Wilson T; de Oliveira, Tássia R; de Correia, Camila R S T B; Faça, Vitor M; de Morais, Beatriz P; Silvestrini, Virginia C; Pott-Junior, Henrique; Teixeira, Felipe R; Faria, Ronaldo C.
Afiliação
  • Nascimento ED; Department of Chemistry, Federal University of São Carlos-UFSCar, Rod. Washington Luís km 235, São Carlos, SP, 13565-905, Brazil.
  • Fonseca WT; Department of Chemistry, Federal University of São Carlos-UFSCar, Rod. Washington Luís km 235, São Carlos, SP, 13565-905, Brazil.
  • de Oliveira TR; Department of Chemistry, Federal University of São Carlos-UFSCar, Rod. Washington Luís km 235, São Carlos, SP, 13565-905, Brazil.
  • de Correia CRSTB; Department of Genetics and Evolution, Federal University of Sao Carlos-UFSCar, São Carlos, SP, 13565-905, Brazil.
  • Faça VM; Department of Biochemistry and Immunology, Ribeirão Preto Medical School, University of São Paulo-USP, Brazil.
  • de Morais BP; Department of Biochemistry and Immunology, Ribeirão Preto Medical School, University of São Paulo-USP, Brazil.
  • Silvestrini VC; Department of Biochemistry and Immunology, Ribeirão Preto Medical School, University of São Paulo-USP, Brazil.
  • Pott-Junior H; Department of Medicine, Federal University of São Carlos-UFSCar, São Carlos, SP, 13565-905, Brazil.
  • Teixeira FR; Department of Genetics and Evolution, Federal University of Sao Carlos-UFSCar, São Carlos, SP, 13565-905, Brazil.
  • Faria RC; Department of Chemistry, Federal University of São Carlos-UFSCar, Rod. Washington Luís km 235, São Carlos, SP, 13565-905, Brazil.
Sens Actuators B Chem ; 353: 131128, 2022 Feb 15.
Article em En | MEDLINE | ID: mdl-34866796
ABSTRACT
The outbreak of the COVID-19 pandemic, caused by Severe Acute Respiratory Syndrome of Coronavirus 2 (SARS-CoV-2), has fueled the search for diagnostic tests aiming at the control and reduction of the viral transmission. The main technique used for diagnosing the Coronavirus disease (COVID-19) is the reverse transcription-polymerase chain reaction (RT-PCR) technique. However, considering the high number of cases and the underlying limitations of the RT-PCR technique, especially with regard to accessibility and cost of the test, one does not need to overemphasize the need to develop new and less expensive testing techniques that can aid the early diagnosis of the disease. With that in mind, we developed an ultrasensitive magneto-assay using magnetic beads and gold nanoparticles conjugated to human angiotensin-converting enzyme 2 (ACE2) peptide (Gln24-Gln42) for the capturing and detection of SARS-CoV-2 Spike protein in human saliva. The technique applied involved the use of a disposable electrochemical device containing eight screen-printed carbon electrodes which allow the simultaneous analysis of eight samples. The magneto-assay exhibited an ultralow limit of detection of 0.35 ag mL-1 for the detection of SARS-CoV-2 Spike protein in saliva. The magneto-assay was tested in saliva samples from healthy and SARS-CoV-2-infected individuals. In terms of efficiency, the proposed technique - which presented a sensitivity of 100.0% and specificity of 93.7% for SARS-CoV-2 Spike protein-exhibited great similarity with the RT-PCR technique. The results obtained point to the application potential of this simple, low-cost magneto-assay for saliva-based point-of-care COVID-19 diagnosis.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies / Screening_studies Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies / Screening_studies Idioma: En Ano de publicação: 2022 Tipo de documento: Article