Paroxysmal atrioventricular block induced during paroxysmal intra-atrial reentrant tachycardia.
J Cardiol Cases
; 24(5): 240-243, 2021 Nov.
Article
em En
| MEDLINE
| ID: mdl-34868406
Paroxysmal atrio-ventricular (AV) block is a relatively rare form of bradyarrhythmia that may be caused by vagal reflex, intrinsic His-Prukinje system (HPS) disorder, or idiopathic mechanisms. We report a case with paroxysmal AV block and syncopal episodes that appeared only during intra-atrial reentrant tachycardia (IART) after an ablation procedure. Syncope did not occur under sinus rhythm with stable 1:1 AV conduction. An HPS disorder was proven in an electrophysiological study. It was suggested that paroxysmal AV block was induced via a tachycardia-dependent mechanism with an exacerbation of latent HPS disorder. The occurrence of the IART was only transient, and there was no recurrent syncope during one-year follow-up. Pacemaker implantation could be avoided. .
Texto completo:
1
Base de dados:
MEDLINE
Idioma:
En
Ano de publicação:
2021
Tipo de documento:
Article