Total robotic choledochal cyst excision with Roux-en-Y hepaticojejunostomy in adults.
Varshney, Vaibhav Kumar; Swami, Ashish.
Afiliação
  • Varshney VK; Department of Surgical Gastroenterology, All India Institute of Medical Sciences, Basni Industrial Area, Phase-II, Jodhpur, Rajasthan, 342005, India. drvarshney09@gmail.com.
  • Swami A; Department of Surgical Gastroenterology, All India Institute of Medical Sciences, Basni Industrial Area, Phase-II, Jodhpur, Rajasthan, 342005, India.
Langenbecks Arch Surg ; 407(4): 1727-1732, 2022 Jun.
Article em En | MEDLINE | ID: mdl-34993610
ABSTRACT

INTRODUCTION:

Choledochal cyst (CDC) excision with bilio-enteric anastomosis has been reported by a laparoscopic approach. With the advent of robotic surgery, it is likely to simplify the performance of such complex procedures. Herein, we present our technique of total robotic CDC excision with intra-corporeal Roux-en-Y hepaticojejunostomy (RYHJ).

METHODS:

The patient was placed in a reverse Trendelenburg position. The robotic ports were placed in a "C"-shaped manner, with the camera port placed ~2 cm below the umbilicus. A 12-mm assistant port was placed in between the camera and the left-sided robotic port. Robotic dissection and excision of extrahepatic part CDC were performed, and subsequently, intra-corporeal robotic RYHJ with jejunojejunostomy was completed. Intra-operatively, indocyanine green dye was used to delineate the biliary anatomy and to check the anastomotic integrity.

RESULTS:

All three patients were female with a median age of 21 (18-34) years. Two patients had type IVa, and one had a mixed variant of type I(C) with type VI. The median operative time was 420 min, whereas docking and console time was 22 (20-25) min and 400 (360-450) min, respectively. The median blood loss and length of hospital stay were 50 (50-100) ml and 6 (5-6) days, respectively. One patient has mild acute pancreatitis in the post-operative period, which was managed conservatively.

CONCLUSION:

Robotic CDC excision and reconstruction seem to be a safe, feasible, and effective surgical option that provides the benefits of minimal access surgery but also greatly aids in complex dissection and reconstruction.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Pancreatite / Cisto do Colédoco / Laparoscopia / Procedimentos Cirúrgicos Robóticos Tipo de estudo: Observational_studies Limite: Adult / Female / Humans / Male Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Pancreatite / Cisto do Colédoco / Laparoscopia / Procedimentos Cirúrgicos Robóticos Tipo de estudo: Observational_studies Limite: Adult / Female / Humans / Male Idioma: En Ano de publicação: 2022 Tipo de documento: Article