Influence of Charge on Hemocompatibility and Immunoreactivity of Polymeric Nanoparticles.
ACS Appl Bio Mater
; 1(3): 756-767, 2018 Sep 17.
Article
em En
| MEDLINE
| ID: mdl-34996166
The benefits of nanomedicine may be restricted by hemocompatibility and immunoreactivity problems arising from administration of exogenous materials into the bloodstream. To understand how surface charge influences the interaction of polymeric nanoparticles with blood components, we synthesized three well-defined, charge-varied hyperbranched polymers (HBPs) of similar size and analyzed both hemocompatibility and immunoreactivity of these methacrylate-based HBPs ex vivo using primary human blood cell assays and image analyses following intravenous injection into mice. The results show that, regardless of charge, endotoxin-free HBPs had minimal effects on coagulation, platelet, complement, or T cell activation. However, high concentrations (100 µg mL-1) of cationic HBPs led to significant dendritic cell activation, suggesting the potential application of these nanoparticles as vaccine adjuvants to aid efficient antigen presentation. Biodistribution studies showed that intravenously administered charge-neutral HBPs had a longer retention time in the circulation than cationic or anionic HBPs; whereas these neutral HBPs were eventually cleared in the urine, charged HBPs mainly accumulated in liver and spleen. Overall, these results demonstrate that, regardless of surface charge, HBPs display a high level of hemocompatibility. In contrast, immunoreactivity and biodistribution are significantly influenced by charge. Manipulation of surface charge may thus be a useful method by which nanomaterials such as HBPs can be tailored to different clinical applications.
Texto completo:
1
Base de dados:
MEDLINE
Idioma:
En
Ano de publicação:
2018
Tipo de documento:
Article