Simple construction of a two-component fluorescent sensor for turn-on detection of Hg2+ in human serum.
Geng, Fenghua; Wang, Dandan; Shao, Congying; Li, Guixin; Xu, Maotian; Feng, Li.
Afiliação
  • Geng F; National Engineering Research Center of Coal Preparation & Purification, Key Laboratory of Coal Processing & Efficient Utilization of Ministry of Education, School of Chemical Engineering & Technology, China University of Mining & Technology, Xuzhou, 221116, China.
  • Wang D; Henan Key Laboratory of Biomolecular Recognition & Sensing, College of Chemistry & Chemical Engineering, Henan Joint International Research Laboratory of Chemo/Biosensing & Early Diagnosis of Major Diseases, Shangqiu Normal University, Shangqiu, 476000, China.
  • Shao C; College of Chemistry & Chemical Engineering, Xinjiang Normal University, Urumqi, 830054, China.
  • Li G; College of Chemistry & Material Science, Huaibei Normal University, Huaibei, 235000, China.
  • Xu M; College of Chemistry & Chemical Engineering, Xinjiang Normal University, Urumqi, 830054, China. liguixin2@163.com.
  • Feng L; Henan Key Laboratory of Biomolecular Recognition & Sensing, College of Chemistry & Chemical Engineering, Henan Joint International Research Laboratory of Chemo/Biosensing & Early Diagnosis of Major Diseases, Shangqiu Normal University, Shangqiu, 476000, China. xumaotian@sqnu.edu.cn.
Anal Bioanal Chem ; 414(5): 2021-2028, 2022 Feb.
Article em En | MEDLINE | ID: mdl-35013805
ABSTRACT
The simply constructed fluorescent sensor with inexpensive reagents and low toxicity has attracted increasing attention contributing to its practical application. However, the common construction methods usually required a few building blocks and complex procedures, which is inconvenient for their further application. Herein, a simply constructed fluorescent Hg2+ sensor has been developed based on the intrinsic fluorescence quenching power of G-quadruplex. Two components, AGRO 100 and AMT, were used to construct the sensor. AMT was selected as the fluorescent probe because of its distinct merits. The free AMT emits strongly. However, the fluorescence of AMT could be quenched by G-quadruplex DNA. Additionally, AMT is less toxic and inexpensive. AGRO 100 acts as both the quencher and the capture sequence because it consists of G-rich sequences and T-T mismatched base pairs. The fluorescence of AMT could be quenched by the formed G-quadruplex structure of AGRO 100 in the presence of K+. In the presence of Hg2+, G-quadruplex structure of AGRO 100 was switched to hairpin DNA structure because T-T mismatched base pairs in AGRO 100 could specifically recognize and capture Hg2+ with high affinity. Thus, AMT was released and the fluorescence of AMT was recovered. The developed sensing system was successfully applied to detect Hg2+ in human serum with good recovery and reproducibility.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Mercúrio Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Mercúrio Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article