Your browser doesn't support javascript.
loading
Liquid chromatography-mass spectrometry method for the determination of polyethylene terephthalate and polybutylene terephthalate cyclic oligomers in blood samples.
Diamantidou, Dimitra; Mastrogianni, Orthodoxia; Tsochatzis, Emmanouil; Theodoridis, Georgios; Raikos, Nikolaos; Gika, Helen; Kalogiannis, Stavros.
Afiliação
  • Diamantidou D; Laboratory of Analytical Chemistry, Department of Chemistry, Aristotle University of Thessaloniki, 54124, Thessaloniki, Greece.
  • Mastrogianni O; Biomic_AUTh, Center for Interdisciplinary Research and Innovation (CIRI-AUTH), Balkan Center, B1.4, 10th km Thessaloniki-Thermi Rd, P.O. Box 8318, 57001, Thessaloniki, Greece.
  • Tsochatzis E; Laboratory of Toxicology, Forensic Service of Thessaloniki, 56334, Thessaloniki, Greece.
  • Theodoridis G; Department of Food Science, iFOOD, Centre for Innovative Food Research, Aarhus University, Agro Food Park 48, 8200, Aarhus, Denmark.
  • Raikos N; European Food Safety Authority-EFSA, Via Carlo Magno 1A, Parma, 43126, Italy.
  • Gika H; Laboratory of Analytical Chemistry, Department of Chemistry, Aristotle University of Thessaloniki, 54124, Thessaloniki, Greece.
  • Kalogiannis S; Biomic_AUTh, Center for Interdisciplinary Research and Innovation (CIRI-AUTH), Balkan Center, B1.4, 10th km Thessaloniki-Thermi Rd, P.O. Box 8318, 57001, Thessaloniki, Greece.
Anal Bioanal Chem ; 414(4): 1503-1512, 2022 Feb.
Article em En | MEDLINE | ID: mdl-35024915
ABSTRACT
Food contact materials (FCM) polyethylene terephthalate (PET) and polybutylene terephthalate (PBT) used extensively in food packaging may contain cyclic oligomers which may migrate into food and thus cause toxic effects on human health. A simple, fast, and sensitive ultra-high-performance liquid chromatography method quadrupole time-of-flight mass spectrometer was developed for the analysis of 7 cyclic oligomers in post-mortem blood samples. The targeted analytes were separated on a Waters BEH C18 (150 × 2.1 mm, 1.7 µm) analytical column by gradient elution. Calibration curves were constructed based on standard solutions and blood samples and Student's t-test was applied to evaluate the matrix effect. The LODs ranged from 1.7 to 16.7 µg mL-1, while the method accuracy was assessed by recovery experiments and resulting within the range 84.2-114.6%. Such an analytical method for the determination of PET and PBT cyclic oligomers in biological samples is reported for the first time. The developed methodology allows the determination of these oligomers in blood providing a useful analytical tool to assess the exposure and thus the potential hazard and health risks associated with these non-intentionally added substances (NIAS) from PET and PBT FCM through food consumption. The method was validated and successfully applied to the analysis of 34 post-mortem whole blood samples. Polyethylene terephthalate trimer was detected in four of them, for the first time in literature.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Poliésteres / Espectrometria de Massas / Análise Química do Sangue / Cromatografia Líquida de Alta Pressão / Polietilenotereftalatos Tipo de estudo: Diagnostic_studies Limite: Aged / Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Poliésteres / Espectrometria de Massas / Análise Química do Sangue / Cromatografia Líquida de Alta Pressão / Polietilenotereftalatos Tipo de estudo: Diagnostic_studies Limite: Aged / Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article