Your browser doesn't support javascript.
loading
Validity and reliability of the Tampa Kinesiophobia-Fatigue Scale in patients with multiple sclerosis.
Kese, Burak; Salci, Yeliz; Yilmaz, Öznur Tunca.
Afiliação
  • Kese B; Osmaneli Vocational School, Department of Patient Care at Home, Bilecik Seyh Edebali University, Bilecik, Turkey. keseburak@gmail.com.
  • Salci Y; Faculty of Physiotherapy and Rehabilitation, Department of Neurologic Physiotherapy and Rehabilitation, Hacettepe University, Ankara, Turkey.
  • Yilmaz ÖT; Faculty of Physiotherapy and Rehabilitation, Department of Neurologic Physiotherapy and Rehabilitation, Hacettepe University, Ankara, Turkey.
Ir J Med Sci ; 192(1): 285-290, 2023 Feb.
Article em En | MEDLINE | ID: mdl-35094232
BACKGROUND: Kinesiophobia can be a barrier for physical activity in patients with multiple sclerosis (PwMS) and it can develop as a result of fear and avoidance reactions due to fatigue. However, there is no valid and reliable scale available to assess kinesiophobia due to fatigue in PwMS. AIMS: To investigate the test-retest reliability and construct validity of the Tampa Scale of Kinesiophobia-Fatigue (TSK-F) in PwMS. METHODS: Eighty-seven PwMS were included in the study. In addition to TSK-F, the following measurements were used for construct validity: Expanded Disability Status Scale (EDSS), Fatigue Severity Scale (FSS), Fatigue Impact Scale (FIS), 6-Minute Walking Test (6MWT), International Physical Activity Questionnaire (IPAQ), Beck Depression Inventory (BDI), Multiple Sclerosis Quality of Life Scale-54 (MSQoL-54). TSK-F was administered twice (3-7 days apart) to measure test-retest reliability. RESULTS: The intraclass correlation coefficient of the TSK-F was 0.867. It had a weak correlation with the IPAQ and EDSS, moderate correlation with the MSQoL-54 and 6MWT, and strong correlation with the BDI, FSS, and FIS (respectively, rho - 0.345, rho 0.365, rho 0.544, rho - 0.449, rho 0.690, rho 0.602, rho 0.650). The scale had good performance to discriminate the disease severity with the area under the curve (AUC) value 0.730. CONCLUSIONS: TSK-F has excellent reliability and moderate-to-good validity in evaluating kinesiophobia and the scale may be a useful outcome measurement for assessment of kinesiophobia due to fatigue in PwMS.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Cinesiofobia / Esclerose Múltipla Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Cinesiofobia / Esclerose Múltipla Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article