Design and ergonomic assessment of a passive head/neck supporting exoskeleton for overhead work use.
Garosi, Ehsan; Mazloumi, Adel; Jafari, Amir Homayoun; Keihani, Ahmadreza; Shamsipour, Mansour; Kordi, Ramin; Kazemi, Zeinab.
Afiliação
  • Garosi E; Department of Occupational Health Engineering, School of Public Health, Tehran University of Medical Sciences, Iran; Department of Ergonomics, School of Public Health, Iran University of Medical Sciences, Iran.
  • Mazloumi A; Department of Occupational Health Engineering, School of Public Health, Tehran University of Medical Sciences, Iran; Sports Medicine Research Center, Neuroscience Institute, Tehran University of Medical Sciences, Tehran, Iran. Electronic address: amazlomi@tums.ac.ir.
  • Jafari AH; Medical Physics & Biomedical Engineering Department, School of Medicine, Tehran University of Medical Sciences, Tehran, Iran.
  • Keihani A; Medical Physics & Biomedical Engineering Department, School of Medicine, Tehran University of Medical Sciences, Tehran, Iran.
  • Shamsipour M; Department of Research Methodology and Data Analysis, Institute for Environmental Research, Tehran University of Medical Sciences, Tehran, Iran.
  • Kordi R; Sports Medicine Research Center, Neuroscience Institute, Tehran University of Medical Sciences, Tehran, Iran.
  • Kazemi Z; Department of Ergonomics, School of Public Health, Iran University of Medical Sciences, Iran.
Appl Ergon ; 101: 103699, 2022 May.
Article em En | MEDLINE | ID: mdl-35114511
ABSTRACT
Overhead work is an important risk factor associated with musculoskeletal disorders of the neck and shoulder region. This study aimed to propose and evaluate a passive head/neck supporting exoskeleton (HNSE) as a potential ergonomic intervention for overhead work applications. Fourteen male participants were asked to perform a simulated overhead task of fastening/unfastening nut in 4 randomized sessions, characterized by two variables neck extension angle (40% and 80% of neck maximum range of motion) and exoskeleton condition (wearing and not wearing the HNSE). Using the HNSE, significantly alleviated perceived discomfort in the neck (p-value = 0.009), right shoulder (p-value = 0.05) and left shoulder (p-value = 0.02) and reduced electromyographic activity of the right (p-value = 0.005) and left (p-value = 0.01) sternocleidomastoid muscles. However, utilizing the exoskeleton caused a remarkable increase in right (p-value = 0.04) and left (p-value = 0.05) trapezius electromyographic activities. Performance was not significantly affected by the HNSE. Although the HNSE had promising effects with respect to discomfort and muscular activity in the static overhead task, future work is still needed to investigate its effect on performance and to provide support for the generalizability of study results.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Exoesqueleto Energizado Tipo de estudo: Clinical_trials / Risk_factors_studies Limite: Humans / Male Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Exoesqueleto Energizado Tipo de estudo: Clinical_trials / Risk_factors_studies Limite: Humans / Male Idioma: En Ano de publicação: 2022 Tipo de documento: Article