Your browser doesn't support javascript.
loading
Simultaneous electrochemical detection of gallic acid and uric acid with p-tert-butylcalix[4]arene-based coordination polymer/mesoporous carbon composite.
Niu, Xia; Pei, Wen-Yuan; Ma, Ji-Cheng; Yang, Jin; Ma, Jian-Fang.
Afiliação
  • Niu X; Key Laboratory of Polyoxometalate and Reticular Material Chemistry, Faculty of Chemistry, Northeast Normal University, Changchun, 130024, China.
  • Pei WY; Key Laboratory of Polyoxometalate and Reticular Material Chemistry, Faculty of Chemistry, Northeast Normal University, Changchun, 130024, China.
  • Ma JC; Key Laboratory of Polyoxometalate and Reticular Material Chemistry, Faculty of Chemistry, Northeast Normal University, Changchun, 130024, China. majc829@nenu.edu.cn.
  • Yang J; Key Laboratory of Polyoxometalate and Reticular Material Chemistry, Faculty of Chemistry, Northeast Normal University, Changchun, 130024, China.
  • Ma JF; Key Laboratory of Polyoxometalate and Reticular Material Chemistry, Faculty of Chemistry, Northeast Normal University, Changchun, 130024, China. majf247@nenu.edu.cn.
Mikrochim Acta ; 189(3): 93, 2022 02 07.
Article em En | MEDLINE | ID: mdl-35132498
ABSTRACT
Design and synthesis of an efficient electrocatalyst for simultaneous determination of gallic acid (GA) and uric acid (UA) is vital in the biological field. Herein, we synthesized a new p-tert-butylcalix[4]arene-based metal-organic electrocatalyst (Mn-L@MC) by combining Mn-L (H4L = tetrakis[(2-biphenylcarboxyl)oxy]-p-tertbutylcalix[4]arene) and mesoporous carbon (MC) via a simple mechanical grinding method. Synergistic effect between Mn-L and MC made the Mn-L@MC composite behave high-efficiency electrocatalytic performance toward simultaneous detection of GA and UA. Under optimal experimental conditions, the Mn-L@MC-2 electrode material featured relatively wide linear range (0.5-90 µM) for the two analytes, and low determination limits of 0.043 µM for GA and 0.059 µM for UA. The remarkable electrochemical detection behavior of Mn-L@MC-2 electrode material toward GA and UA are comparable to those known sensors containing precious metals. The Mn-L@MC-2 material exhibited high selectivity, superior reproducibility, and acceptable stability during the determination of the two analytes. The sensor was assembled to simultaneously detect GA and UA in healthy human urine with satisfactory recoveries.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Ano de publicação: 2022 Tipo de documento: Article