Your browser doesn't support javascript.
loading
Cuffless Blood Pressure Devices.
Bradley, Corey K; Shimbo, Daichi; Colburn, David Alexander; Pugliese, Daniel N; Padwal, Raj; Sia, Samuel K; Anstey, D Edmund.
Afiliação
  • Bradley CK; The Columbia Hypertension Center and Lab, Columbia University Irving Medical Center, New York, New York, USA.
  • Shimbo D; The Columbia Hypertension Center and Lab, Columbia University Irving Medical Center, New York, New York, USA.
  • Colburn DA; Department of Biomedical Engineering, Columbia University, New York, New York, USA.
  • Pugliese DN; The Columbia Hypertension Center and Lab, Columbia University Irving Medical Center, New York, New York, USA.
  • Padwal R; Department of Medicine, University of Alberta, Edmonton, Alberta, Canada.
  • Sia SK; Department of Biomedical Engineering, Columbia University, New York, New York, USA.
  • Anstey DE; The Columbia Hypertension Center and Lab, Columbia University Irving Medical Center, New York, New York, USA.
Am J Hypertens ; 35(5): 380-387, 2022 05 10.
Article em En | MEDLINE | ID: mdl-35136906
ABSTRACT
Hypertension is associated with more end-organ damage, cardiovascular events, and disability-adjusted life years lost in the United States compared with all other modifiable risk factors. Several guidelines and scientific statements now endorse the use of out-of-office blood pressure (BP) monitoring with ambulatory BP monitoring or home BP monitoring to confirm or exclude hypertension status based on office BP measurement. Current ambulatory or home BP monitoring devices have been reliant on the placement of a BP cuff, typically on the upper arm, to measure BP. There are numerous limitations to this approach. Cuff-based BP may not be well-tolerated for repeated measurements as is utilized with ambulatory BP monitoring. Furthermore, improper technique, including incorrect cuff placement or use of the wrong cuff size, may lead to erroneous readings, affecting diagnosis and management of hypertension. Compared with devices that utilize a cuff, cuffless BP devices may overcome challenges related to technique, tolerability, and overall utility in the outpatient setting. However, cuffless devices have several potential limitations that limit its routine use for the diagnosis and management of hypertension. The review discusses the different approaches for determining BP using various cuffless devices including engineering aspects of cuffless device technologies, validation protocols to test accuracy of cuffless devices, potential barriers to widespread implementation, and future areas of research. This review is intended for the clinicians who utilize out-of-office BP monitoring for the diagnosis and management of hypertension.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Monitorização Ambulatorial da Pressão Arterial / Hipertensão Tipo de estudo: Diagnostic_studies / Guideline / Risk_factors_studies Limite: Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Monitorização Ambulatorial da Pressão Arterial / Hipertensão Tipo de estudo: Diagnostic_studies / Guideline / Risk_factors_studies Limite: Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article