Your browser doesn't support javascript.
loading
Finite Element Modeling of Planus and Rectus Foot Types for the Study of First Metatarsophalangeal and First Metatarsocuneiform Joint Contact Mechanics.
Morgan, Oliver J; Hillstrom, Howard J; Bitar, Rogerio; Sturnick, Daniel; Koff, Matthew F; Ellis, Scott J; Deland, Jonathan T; Hillstrom, Rajshree.
Afiliação
  • Morgan OJ; Faculty of Science and Engineering, Anglia Ruskin University, Chelmsford, Essex CM1 1SQ, UK.
  • Hillstrom HJ; Leon Root, MD Motion Analysis Laboratory, Hospital for Special Surgery, New York, NY 10021.
  • Bitar R; Department of Biomechanics, Hospital for Special Surgery, New York, NY 10021.
  • Sturnick D; Department of Biomechanics, Hospital for Special Surgery, New York, NY 10021.
  • Koff MF; Department of Radiology and Imaging, Hospital for Special Surgery, New York, NY 10021.
  • Ellis SJ; Department of Orthopedics, Foot and Ankle Division, Hospital for Special Surgery, New York, NY 10021.
  • Deland JT; Department of Orthopedics, Foot and Ankle Division, Hospital for Special Surgery, New York, NY 10021.
  • Hillstrom R; Biomed Consulting, Inc., New York, NY 10044.
J Biomech Eng ; 144(8)2022 08 01.
Article em En | MEDLINE | ID: mdl-35147162
ABSTRACT
The foot is a highly complex biomechanical system for which finite element (FE) modeling has been used to evaluate its loading environment. However, there is limited knowledge of first metatarsophalangeal (MTP) and first metatarsocuneiform (MTC) joint contact mechanics. Our goal was to develop a framework for FE modeling of the medial forefoot which could accurately predict experimental measurements of first MTP and first MTC joint loading. Simulations of planus and rectus foot types were conducted for midstance of gait. A custom-built force-controlled cadaveric test-rig was used to derive intracapsular pressure sensor measurements of contact pressure, force, and area during quasi-static loading. The FE model was driven under the same boundary and loading conditions as the cadaver. Mesh sensitivity analyses and best-fit calibrations of moduli for first MTP and first MTC joint cartilage were performed. Consistent with previous experimental research, a lower compressive modulus was best-fit to the first MTP compared to first MTC joint at 10 MPa and 20 MPa, respectively. Mean errors in contact pressures, forces, and areas were 24%, 4%, and 40% at the first MTP joint and 23%, 12%, and 19% at the first MTC joint, respectively. The present developmental framework may provide a basis for future modeling of first MTP and first MTC joint contact mechanics. This study acts as a precursor to validation of realistic physiological loading across gait to investigate joint loading, foot type biomechanics, and surgical interventions of the medial forefoot.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Pé / Articulação Metatarsofalângica Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Pé / Articulação Metatarsofalângica Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article