Glasses-Assisted 3D Display System-Guided Descemet Membrane Endothelial Keratoplasty Tissue Preparation.
Borroni, Davide; Rocha-de-Lossada, Carlos; Bonci, Paola; Rechichi, Miguel; Rodríguez-Calvo-de-Mora, Marina; Rachwani-Anil, Rahul; Sánchez González, Jose' Maria; Urbinati, Facundo; Lorente, María García; Vigo, Luca; Carones, Francesco.
Afiliação
  • Borroni D; Department of Doctoral Studies, Riga Stradins University, Riga, Latvia.
  • Rocha-de-Lossada C; Advalia Vision, Cornea Research Unit, Milan, Italy.
  • Bonci P; Department of Ophthalmology, Qvision (Vithas Almeria).
  • Rechichi M; University Hospital Virgen de Las Nieves, Granada, Spain.
  • Rodríguez-Calvo-de-Mora M; Department of Ophthalmology, Ceuta Medical Center, Ceuta, Spain.
  • Rachwani-Anil R; Ospedale Civile di Ravenna, Banca Delle Cornee Della Regione Emilia-Romagna.
  • Sánchez González JM; Centro Polispecialistico Mediterraneo, Sellia Marina, Italy.
  • Urbinati F; Department of Ophthalmology, Qvision (Vithas Almeria).
  • Lorente MG; Regional University Hospital of Malaga, 29010 Malaga, Spain.
  • Vigo L; Department of Opthalmology, Hospital de Antequera, Malaga, Spain; and.
  • Carones F; Department of Physics of Condensed Matter, Optics Area. University of Seville, Seville, Spain.
Cornea ; 41(11): 1444-1446, 2022 Nov 01.
Article em En | MEDLINE | ID: mdl-35184124
PURPOSE: The aim of this study was to evaluate the feasibility of Descemet membrane endothelial keratoplasty (DMEK) tissue preparation using a glasses-assisted 3-dimensional (3D) display system and to compare it with a conventional surgical microscope. METHODS: Healthy pairs of human corneas suitable for penetrating keratoplasty surgery were selected for this study. The tissues were randomly divided into 2 groups. Each pair of corneas had 1 cornea (group 1) prepared with NGENUITY (Alcon) with a 5-second staining time with vision blue, and the fellow cornea (group 2) was prepared using a OPMI Lumera 700 surgical microscope (Carl Zeiss Meditec, Jena, Germany) with a 30-second staining time. DMEK graft preparation time, speed of stripping, graft width, and endothelial cell loss were evaluated. RESULTS: Twenty-eight pairs of corneas were included in this study. The graft preparation time was significantly higher in the 3D group than in the conventional group (498 ± 147 vs. 418 ± 85 seconds, P value = 0.031). The mean speed of stripping was 0.59 ± 0.081 mm/s in group 1 and 0.089 ± 0.005 mm/s in group 2 ( P value = 0.024). The mean endothelial cell density in group 1 and group 2 before tissue preparation was 2162 ± 115.21 and 2153 ± 122.45, respectively ( P value > 0.1). After tissue preparation, the endothelial cell density reduced to 1911 ± 150.72 in group 1 and 1998 ± 90.72 in group 2 ( P value = P value > 0.05). The graft width was 5.05 ± 0.71 mm in group 1 and 4.92 ± 0.23 mm in group 2 ( P value > 0.05). CONCLUSIONS: DMEK tissue preparation with 3D display system NGENUITY is feasible with a slightly increased preparation time. The improved visualization allows a reduced staining time that could be beneficial for eye banks because it may reduce the toxic effect of staining colorants.