Development, validation and application of a UHPLC-MS/MS method for quantification of the adiponectin-derived active peptide ADP355 in rat plasma.
Li, Qiaoxi; Jiang, Fulin; Guan, Yanping; Jiang, Xianxing; Wu, Junyan; Huang, Min; Zhong, Guoping.
Afiliação
  • Li Q; Institute of Clinical Pharmacology, School of Pharmaceutical Sciences, Sun Yat-sen University, Guangzhou City, Guangdong Province, China.
  • Jiang F; Guangdong Provincial Key Laboratory of New Drug Design and Evaluation, School of Pharmaceutical Sciences, Sun Yat-Sen University, Guangzhou, China.
  • Guan Y; Institute of Clinical Pharmacology, School of Pharmaceutical Sciences, Sun Yat-sen University, Guangzhou City, Guangdong Province, China.
  • Jiang X; Guangdong Provincial Key Laboratory of New Drug Design and Evaluation, School of Pharmaceutical Sciences, Sun Yat-Sen University, Guangzhou, China.
  • Wu J; Department of Pharmacy, Sun Yat-Sen Memorial Hospital, Sun Yat-Sen University, Guangzhou, China.
  • Huang M; School of Pharmaceutical Sciences, Sun Yat-Sen University, Guangzhou, China.
  • Zhong G; Department of Pharmacy, Sun Yat-Sen Memorial Hospital, Sun Yat-Sen University, Guangzhou, China.
Biomed Chromatogr ; 36(6): e5358, 2022 Jun.
Article em En | MEDLINE | ID: mdl-35187696
ABSTRACT
A UHPLC-MS/MS method for the quantification of ADP355, an adiponectin-derived active peptide, was developed and validated. The extraction method employed simple protein precipitation using methanol and chromatographic separation was achieved on anAccucore™ RP-MS C18 column (100 × 2.1 mm, 2.6 µm, 80 Å), using 0.1% formic acid in both water and acetonitrile with gradient elution at the flow rate of 400 µl/min within 4.0 min. Detections were performed under positive ion mode with multiple reaction monitoring ion transitions m/z 1109.2 → 309.8 and 871.4 → 310.1 for ADP355 and Jt003 respectively at unit resolution. The linearity range of the calibration curve was 2-1,000 ng/ml with a lower limit detection of 0.5 ng/ml. The selectivity, linearity, precision, accuracy, recovery, matrix effect and stability were validated, and all items met the requirement of US Food and Drug Administration guidance. This method was successfully applied to an intravenous pharmacokinetic study of ADP355 in rats and the in-vitro stability in rat serum, plasma and whole blood was also assessed.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Oligopeptídeos / Cromatografia Líquida de Alta Pressão / Adiponectina / Espectrometria de Massas em Tandem Limite: Animals Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Oligopeptídeos / Cromatografia Líquida de Alta Pressão / Adiponectina / Espectrometria de Massas em Tandem Limite: Animals Idioma: En Ano de publicação: 2022 Tipo de documento: Article