Your browser doesn't support javascript.
loading
Evaluating of IAQ-Index and TVOC Parameter-Based Sensors for Hazardous Gases Detection and Alarming Systems.
Al-Okby, Mohammed Faeik Ruzaij; Neubert, Sebastian; Roddelkopf, Thomas; Fleischer, Heidi; Thurow, Kerstin.
Afiliação
  • Al-Okby MFR; Technical Institute of Babylon, Al-Furat Al-Awsat Technical University (ATU), Kufa 54003, Iraq.
  • Neubert S; Center for Life Science Automation (Celisca), University of Rostock, 18119 Rostock, Germany.
  • Roddelkopf T; Leibniz Institute for Baltic Sea Research Warnemünde, 18119 Rostock, Germany.
  • Fleischer H; Institute of Automation, University of Rostock, 18119 Rostock, Germany.
  • Thurow K; Institute of Automation, University of Rostock, 18119 Rostock, Germany.
Sensors (Basel) ; 22(4)2022 Feb 14.
Article em En | MEDLINE | ID: mdl-35214376
ABSTRACT
The measurement of air quality parameters for indoor environments is of increasing importance to provide sufficient safety conditions for workers, especially in places including dangerous chemicals and materials such as laboratories, factories, and industrial locations. Indoor air quality index (IAQ-index) and total volatile organic Compounds (TVOC) are two important parameters to measure air impurities or air pollution. Both parameters are widely used in gases sensing applications. In this paper, the IAQ-index and TVOCs have been investigated to identify the best and most flexible solution for air quality threshold selection of hazardous/toxic gases detection and alarming systems. The TVOCs from the SGP30 gas sensor and the IAQ-index from the SGP40 gas sensor were tested with 12 different organic solvents. The two gas sensors are combined with an IoT-based microcontroller for data acquisition and data transfer to an IoT-cloud for further processing, storing, and monitoring purposes. Extensive tests of both sensors were carried out to determine the minimum detectable volume depending on the distance between the sensor node and the leakage source. The test scenarios included static tests in a classical chemical hood, as well as tests with a mobile robot in an automated sample preparation laboratory with different positions.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Poluição do Ar em Ambientes Fechados / Poluentes Atmosféricos / Compostos Orgânicos Voláteis Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article