ID23-2: an automated and high-performance microfocus beamline for macromolecular crystallography at the ESRF.
Nanao, Max; Basu, Shibom; Zander, Ulrich; Giraud, Thierry; Surr, John; Guijarro, Matias; Lentini, Mario; Felisaz, Franck; Sinoir, Jeremy; Morawe, Christian; Vivo, Amparo; Beteva, Antonia; Oscarsson, Marcus; Caserotto, Hugo; Dobias, Fabien; Flot, David; Nurizzo, Didier; Gigmes, Jonathan; Foos, Nicolas; Siebrecht, Ralf; Roth, Thomas; Theveneau, Pascal; Svensson, Olof; Papp, Gergely; Lavault, Bernard; Cipriani, Florent; Barrett, Ray; Clavel, Carole; Leonard, Gordon.
Afiliação
  • Nanao M; European Synchrotron Radiation Facility, 71 Avenue des Martyrs, F-38000 Grenoble, France.
  • Basu S; European Molecular Biology Laboratory, 71 Avenue des Martyrs, 38042 Grenoble, France.
  • Zander U; European Molecular Biology Laboratory, 71 Avenue des Martyrs, 38042 Grenoble, France.
  • Giraud T; European Synchrotron Radiation Facility, 71 Avenue des Martyrs, F-38000 Grenoble, France.
  • Surr J; European Synchrotron Radiation Facility, 71 Avenue des Martyrs, F-38000 Grenoble, France.
  • Guijarro M; European Synchrotron Radiation Facility, 71 Avenue des Martyrs, F-38000 Grenoble, France.
  • Lentini M; European Synchrotron Radiation Facility, 71 Avenue des Martyrs, F-38000 Grenoble, France.
  • Felisaz F; European Molecular Biology Laboratory, 71 Avenue des Martyrs, 38042 Grenoble, France.
  • Sinoir J; European Molecular Biology Laboratory, 71 Avenue des Martyrs, 38042 Grenoble, France.
  • Morawe C; European Synchrotron Radiation Facility, 71 Avenue des Martyrs, F-38000 Grenoble, France.
  • Vivo A; European Synchrotron Radiation Facility, 71 Avenue des Martyrs, F-38000 Grenoble, France.
  • Beteva A; European Synchrotron Radiation Facility, 71 Avenue des Martyrs, F-38000 Grenoble, France.
  • Oscarsson M; European Synchrotron Radiation Facility, 71 Avenue des Martyrs, F-38000 Grenoble, France.
  • Caserotto H; European Synchrotron Radiation Facility, 71 Avenue des Martyrs, F-38000 Grenoble, France.
  • Dobias F; European Synchrotron Radiation Facility, 71 Avenue des Martyrs, F-38000 Grenoble, France.
  • Flot D; European Synchrotron Radiation Facility, 71 Avenue des Martyrs, F-38000 Grenoble, France.
  • Nurizzo D; European Synchrotron Radiation Facility, 71 Avenue des Martyrs, F-38000 Grenoble, France.
  • Gigmes J; European Synchrotron Radiation Facility, 71 Avenue des Martyrs, F-38000 Grenoble, France.
  • Foos N; European Synchrotron Radiation Facility, 71 Avenue des Martyrs, F-38000 Grenoble, France.
  • Siebrecht R; ARINAX, 365 Rue de Corporat, 38430 Moirans, France.
  • Roth T; European Synchrotron Radiation Facility, 71 Avenue des Martyrs, F-38000 Grenoble, France.
  • Theveneau P; European Synchrotron Radiation Facility, 71 Avenue des Martyrs, F-38000 Grenoble, France.
  • Svensson O; European Synchrotron Radiation Facility, 71 Avenue des Martyrs, F-38000 Grenoble, France.
  • Papp G; European Synchrotron Radiation Facility, 71 Avenue des Martyrs, F-38000 Grenoble, France.
  • Lavault B; ARINAX, 365 Rue de Corporat, 38430 Moirans, France.
  • Cipriani F; European Molecular Biology Laboratory, 71 Avenue des Martyrs, 38042 Grenoble, France.
  • Barrett R; European Synchrotron Radiation Facility, 71 Avenue des Martyrs, F-38000 Grenoble, France.
  • Clavel C; European Synchrotron Radiation Facility, 71 Avenue des Martyrs, F-38000 Grenoble, France.
  • Leonard G; European Synchrotron Radiation Facility, 71 Avenue des Martyrs, F-38000 Grenoble, France.
J Synchrotron Radiat ; 29(Pt 2): 581-590, 2022 Mar 01.
Article em En | MEDLINE | ID: mdl-35254323
ABSTRACT
ID23-2 is a fixed-energy (14.2 keV) microfocus beamline at the European Synchrotron Radiation Facility (ESRF) dedicated to macromolecular crystallography. The optics and sample environment have recently been redesigned and rebuilt to take full advantage of the upgrade of the ESRF to the fourth generation Extremely Brilliant Source (ESRF-EBS). The upgraded beamline now makes use of two sets of compound refractive lenses and multilayer mirrors to obtain a highly intense (>1013 photons s-1) focused microbeam (minimum size 1.5 µm × 3 µm full width at half-maximum). The sample environment now includes a FLEX-HCD sample changer/storage system, as well as a state-of-the-art MD3Up high-precision multi-axis diffractometer. Automatic data reduction and analysis are also provided for more advanced protocols such as synchrotron serial crystallographic experiments.