In Vivo Comparison of Backscatter Techniques for Ultrasonic Bone Assessment at the Femoral Neck.
Hoffmeister, Brent K; Delahunt, Sarah I; Downey, Kiera L; Viano, Ann M; Thomas, Doni M; Georgiou, Loukas A; Gray, Aubrey J; Newman, Will R; Main, Evan N; Pirro, Gia.
Afiliação
  • Hoffmeister BK; Department of Physics, Rhodes College, Memphis, Tennessee, USA. Electronic address: hoffmeister@rhodes.edu.
  • Delahunt SI; Department of Physics, Rhodes College, Memphis, Tennessee, USA.
  • Downey KL; Department of Physics, Rhodes College, Memphis, Tennessee, USA.
  • Viano AM; Department of Physics, Rhodes College, Memphis, Tennessee, USA.
  • Thomas DM; Department of Physics, Rhodes College, Memphis, Tennessee, USA.
  • Georgiou LA; Department of Physics, Rhodes College, Memphis, Tennessee, USA.
  • Gray AJ; Department of Physics, Rhodes College, Memphis, Tennessee, USA.
  • Newman WR; Department of Physics, Rhodes College, Memphis, Tennessee, USA.
  • Main EN; Department of Physics, Rhodes College, Memphis, Tennessee, USA.
  • Pirro G; Department of Physics, Rhodes College, Memphis, Tennessee, USA.
Ultrasound Med Biol ; 48(6): 997-1009, 2022 06.
Article em En | MEDLINE | ID: mdl-35282987
ABSTRACT
Ultrasonic techniques are being developed to detect changes in cancellous bone caused by osteoporosis. The goal of this study was to test the relative in vivo performance of eight backscatter parameters developed over the last several years for ultrasonic bone assessment apparent integrated backscatter (AIB), frequency slope of apparent backscatter (FSAB), frequency intercept of apparent backscatter (FIAB), normalized mean of the backscatter difference (nMBD), normalized slope of the backscatter difference (nSBD), normalized intercept of the backscatter difference (nIBD), normalized backscatter amplitude ratio (nBAR) and backscatter amplitude decay constant (BADC). Backscatter measurements were performed on the left and right femoral necks of 80 adult volunteers (age = 25 ± 11 y) using an imaging system equipped with a convex array transducer. For comparison, additional ultrasonic measurements were performed at the left and right heel using a commercially available heel-bone ultrasonometer that measured the stiffness index. Six of the eight backscatter parameters (all but nSBD and nIBD) exhibited similar and highly significant (p < 0.000001) left-right correlations (0.51 ≤ R ≤ 0.68), indicating sensitivity to naturally occurring variations in bone tissue. Left-right correlations for the stiffness index measured at the heel (R = 0.75) were not significantly better than those produced by AIB, FSAB and FIAB. The short-term precisions of AIB, nMBD, nBAR and BADC (7.8%-11.7%) were comparable to that of the stiffness index measured with the heel-bone ultrasonometer (7.5%).
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Ultrassom / Colo do Fêmur Tipo de estudo: Diagnostic_studies Limite: Adolescent / Adult / Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article