Your browser doesn't support javascript.
loading
Surface-Functionalized Terahertz Metamaterial Biosensor Used for the Detection of Exosomes in Patients.
Wang, Yao; Wang, Yuanli; Hu, Fangrong; Zeng, Lizhen; Chen, Zhencheng; Jiang, Mingzhu; Lin, Shangjun; Guo, Wei; Li, Dongxia.
Afiliação
  • Wang Y; Guangxi Key Laboratory of Optoelectronic Information Processing, Guilin University of Electronic Technology, Guilin 541004, China.
  • Wang Y; Guangxi Key Laboratory of Optoelectronic Information Processing, Guilin University of Electronic Technology, Guilin 541004, China.
  • Hu F; Precision Medicine Laboratory, The First People's Hospital of Qinzhou, Qinzhou 535000, China.
  • Zeng L; Guangxi Key Laboratory of Optoelectronic Information Processing, Guilin University of Electronic Technology, Guilin 541004, China.
  • Chen Z; Guangxi Key Laboratory of Optoelectronic Information Processing, Guilin University of Electronic Technology, Guilin 541004, China.
  • Jiang M; Guangxi Key Laboratory of Optoelectronic Information Processing, Guilin University of Electronic Technology, Guilin 541004, China.
  • Lin S; Guangxi Key Laboratory of Optoelectronic Information Processing, Guilin University of Electronic Technology, Guilin 541004, China.
  • Guo W; Institute of Information Technology of Guilin, Guilin 541004, China.
  • Li D; Guangxi Key Laboratory of Optoelectronic Information Processing, Guilin University of Electronic Technology, Guilin 541004, China.
Langmuir ; 38(12): 3739-3747, 2022 03 29.
Article em En | MEDLINE | ID: mdl-35298154
ABSTRACT
Owing to their stability in bodily fluids, exosomes have attracted increased attention as colorectal cancer (CRC) biomarkers for early diagnosis. To validate the potential of the plasma exosomes as a novel biomarker for the monitoring of CRC, we demonstrated a terahertz (THz) metamaterials (MMs) biosensor for the detection of exosomes in this work. The biosensor with two resonant frequencies is designed using full wave electromagnetic simulation software based on the finite integration time domain (FITD) method and fabricated by a surface micromachining process. The biosensor surface is first modified using Au nanoparticles (AuNPs), and then, anti-KRAS and anti-CD147, which are specific to the exosomes, are modified on the AuNPs assembled with HS-poly(ethylene glycol)-COOH (HS-PEG-COOH). Exosomes used in the experiment are extracted via the instructions in the exosomes isolation and purification kit and identified by using transmission electron microscopy (TEM), Western blot (WB), and nanoparticle tracking analysis (NTA). The biosensor covered with plasma-derived exosomes of CRC patients has a different resonance frequency shift compared to that with healthy-control-derived exosomes. This study proposes an emerging and quick method for diagnosing the CRC.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Nanopartículas Metálicas / Exossomos Tipo de estudo: Diagnostic_studies / Screening_studies Limite: Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Nanopartículas Metálicas / Exossomos Tipo de estudo: Diagnostic_studies / Screening_studies Limite: Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article