Your browser doesn't support javascript.
loading
Dose Field Shaping and Biological Effectiveness of the Effect of Pulsed Electron Accelerator Novac-11 on Mammalian Cells.
Koryakina, E V; Lychagin, A A; Potetnya, V I; Troshinа, M V; Saburov, V O; Moiseev, A S; Koryakin, S N; Ivanov, S A; Shegai, P V; Kaprin, A D.
Afiliação
  • Koryakina EV; A. F. Tsyb Medical Radiological Research Center - Affiliated Branch of the National Medical Research Radiological Center, Ministry of Health of the Russian Federation, Obninsk, Russia. ek-koryakina@mrrc.obninsk.ru.
  • Lychagin AA; A. F. Tsyb Medical Radiological Research Center - Affiliated Branch of the National Medical Research Radiological Center, Ministry of Health of the Russian Federation, Obninsk, Russia.
  • Potetnya VI; A. F. Tsyb Medical Radiological Research Center - Affiliated Branch of the National Medical Research Radiological Center, Ministry of Health of the Russian Federation, Obninsk, Russia.
  • Troshinа MV; A. F. Tsyb Medical Radiological Research Center - Affiliated Branch of the National Medical Research Radiological Center, Ministry of Health of the Russian Federation, Obninsk, Russia.
  • Saburov VO; A. F. Tsyb Medical Radiological Research Center - Affiliated Branch of the National Medical Research Radiological Center, Ministry of Health of the Russian Federation, Obninsk, Russia.
  • Moiseev AS; A. F. Tsyb Medical Radiological Research Center - Affiliated Branch of the National Medical Research Radiological Center, Ministry of Health of the Russian Federation, Obninsk, Russia.
  • Koryakin SN; A. F. Tsyb Medical Radiological Research Center - Affiliated Branch of the National Medical Research Radiological Center, Ministry of Health of the Russian Federation, Obninsk, Russia.
  • Ivanov SA; A. F. Tsyb Medical Radiological Research Center - Affiliated Branch of the National Medical Research Radiological Center, Ministry of Health of the Russian Federation, Obninsk, Russia.
  • Shegai PV; National Medical Research Radiological Center, Ministry of the Health of the Russian Federation, Obninsk, Russia.
  • Kaprin AD; National Medical Research Radiological Center, Ministry of the Health of the Russian Federation, Obninsk, Russia.
Bull Exp Biol Med ; 172(5): 558-560, 2022 Mar.
Article em En | MEDLINE | ID: mdl-35348959
ABSTRACT
The development of technologies for using the Novac-11 pulsed electron accelerator in radiation therapy of animals with spontaneous neoplasms requires dosimetric and radiobiological studies. The studies were performed on cultured Chinese hamster V-79 fibroblasts after irradiation with 10 MeV electrons in a dose range up to 12 Gy and 60Co γ-radiation. Chemical dosimeters FBX and Fricke were used as additional test-systems. The depth dose curves were measured and the maximum dose depth of the electron beam was determined in tissue-equivalent phantoms. Cell survival and the data of chemical dosimetric systems showed that the effects of electron irradiation did not differ from that of 60Co γ-radiation. It was concluded that the use of Novac-11 in the therapy of animals with spontaneous neoplasms is advisable.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Radiometria / Elétrons Limite: Animals Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Radiometria / Elétrons Limite: Animals Idioma: En Ano de publicação: 2022 Tipo de documento: Article