Accuracy and safety of robot-assisted cortical bone trajectory screw placement: a comparison of robot-assisted technique with fluoroscopy-assisted approach.
BMC Musculoskelet Disord
; 23(1): 328, 2022 Apr 06.
Article
em En
| MEDLINE
| ID: mdl-35387621
OBJECTIVE: To compare the safety and accuracy of cortical bone trajectory screw placement between the robot-assisted and fluoroscopy-assisted approaches. METHODS: This retrospective study was conducted between November 2018 and June 2020, including 81 patients who underwent cortical bone trajectory (CBT) surgery for degenerative lumbar spine disease. CBT was performed by the same team of experienced surgeons. The patients were randomly divided into two groups-the fluoroscopy-assisted group (FA, 44 patients) and the robot-assisted group (RA, 37 patients). Robots for orthopedic surgery were used in the robot-assisted group, whereas conventional fluoroscopy-guided screw placement was used in the fluoroscopy-assisted group. The accuracy of screw placement and rate of superior facet joint violation were assessed using postoperative computed tomography (CT). The time of single screw placement, intraoperative blood loss, and radiation exposure to the surgical team were also recorded. The χ2 test and Student's t-test were used to analyze the significance of the variables (P < 0.05). RESULTS: A total of 376 screws were inserted in 81 patients, including 172 screws in the robot-assisted group and 204 pedicle screws in the fluoroscopy-assisted group. Screw placement accuracy was higher in the RA group (160, 93%) than in the FA group (169, 83%) (P = 0.003). The RA group had a lower violation of the superior facet joint than the FA group. The number of screws reaching grade 0 in the RA group (58, 78%) was more than that in the FA group (56, 64%) (P = 0.041). Screw placement time was longer in the FA group (7.25 ± 0.84 min) than in the RA group (5.58 ± 1.22 min, P < 0.001). The FA group had more intraoperative bleeding (273.41 ± 118.20 ml) than the RA group (248.65 ± 97.53 ml, P = 0.313). The radiation time of the FA group (0.43 ± 0.07 min) was longer than the RA group (0.37 ± 0.10 min, P = 0.001). Furthermore, the overall learning curve tended to decrease. CONCLUSIONS: Robot-assisted screw placement improves screw placement accuracy, shortens screw placement time, effectively improves surgical safety and efficiency, and reduces radiation exposure to the surgical team. In addition, the learning curve of robot-assisted screw placement is smooth and easy to operate.
Palavras-chave
Texto completo:
1
Base de dados:
MEDLINE
Assunto principal:
Fusão Vertebral
/
Robótica
/
Cirurgia Assistida por Computador
/
Procedimentos Cirúrgicos Robóticos
/
Parafusos Pediculares
Tipo de estudo:
Observational_studies
Limite:
Humans
Idioma:
En
Ano de publicação:
2022
Tipo de documento:
Article